15
P2
On/Off
Turning on the boiler , turning off the boiler by pressing the key for more
than 3 seconds after the acoustic signal.
Unblocking
If the system blocked, you can unblock it by pressing this key for more
than 3 seconds after the acoustic signal.
P4
P6
Changing values
Changing values and settings in menus and submenus
Navigating menus and submenus
Navigating (changing) menus and submenus
Visualisation
Access to the visualization menu
P1
Esc
Leaving the current menu or submenu
P3
Menu
Entering the menu or submenu
Modify
Enables changes in the menu
Set
Keeps (records) data in the menu
P5
Reset system maintenance 2
Function
The timer is reset (only if this option is activated)
Manual Stan-by
By pressing the button for more than 3 seconds, the system goes into
the Standby mode.
Led symbols:
Lighter
Led light is on: The lighter is on
Auger
Led light is on: Auger is operating
Pump
Led light is on: Pump is operating
L3
Aux 1 outlet
Led light is on: Aux 1 outlet has been activated
L4
Additional motor
Led light is on: Additional motor has been activated
L5
Aux 2 outlet
Led light is on: Aux 2 outlet has been activated
L6
Aux 3 outlet
Led light is on: Aux 3 outlet has been activated
L7
Not active
L8
Not active
L9
Pellet level sensor
Led light is on: Pellet is missing
External thermostat
Led light is on: Contact is open
Sanitary water switch
Led light is on: Sanitary water is needed
Display:
- Meaning:
Time and date
Chrono modalities (D-Daily, W-Weekly, We-Week-End)
Power system (P1, P2, P3, P4 and P5)
Recipe (Pellet 1)
System states (Check Up, Ignition, Stabilization, Run Mode, Modulation, Standby, Safety, Extinguishing, Recover
Ignition, Block, Off)
-Errors (Alarms):
When an error occurs (alarm), the system enters the Block Phase (Block)
Error code
(Alarm code)
Error(Alarm) description
Er01
Safety thermostat activated
Er02
Safety pressure switch activated
Er03
Turning off due to too low temperature of flue gases
Er04
Turning off due to too high temperature of water in the boiler
Er05
Turning off due to too high temperature of flue gases
Er06
Safety thermostat activated on the auger housing
Er07
An encoder error. A signal is missing