5
ATTENTION: In case the appliance will not be used for a longer period of time (more than 15 days), remove all remaining pellet
from the hopper to avoid humidity increase which can lead to product malfunction.
ATTENTION: Excess humidity of pellet can cause deterioration and create dust, which can lead to increased accumulation in the
boiler area and even blockthe pellet feed system (auger).
When loading the hopper take care not to spill pellets in other interior parts of the product.
Use only pellet of 6 to 8 mm diameter.
General warnings and recommendations
ATTENTION: Carefully read the provided manual before installation.
ATTENTION: The firebox must be emptied before switching on the unitand in case any problems occur when starting the unit.
It is absolutely prohibited touse any other solid or liquid fuel except 6 mm diameter wood pellet. Avoid the use of damp or crushed
pellets.
In order to optimize the appliance functionality it is recommended to usewood pellets certified by accredited body. The use of any
other pellets beside those listed by the manufacturermay result in appliance malfunction and render the warranty void.
Do not use this unit as an incineratoror in any other way except the intended.
ATTENTION: If you cannot ignite the stove you have to empty the firebox. If not cleaned, it can cause an extremely strong
combustion and the creation of large amounts of smoke.
ATTENTION: Do not open the door and do not turn off the power supply during the ignition or extinguishing phase, while the unit
is operational, even if the combustion chamber is blocked or overloaded. Before dealing with the problem start extinguishing phase and give
unit time to shut down. Do not try to reignite the unit before solving the problem.
ATTENTION: Do not interrupt extinguishing process (for example, by unplugging) until it is over.
ATTENTION: If the wood pellet accumulates in the combustion chamber while the unit is operational, switch off the unit and switch
it on with the greater ventilation program. If the pellet is still accumulating, try a different pellet or contact the manufacturer’s assistance
service.
Never load pellet into combustion chamber manually.
Do not attempt any unauthorized modification of the appliance.
INSTALLATION
To successfully install the productand prevent the occurrence of faults you will find a number of simple tips for installation in accordance with
the relevant applicable regulations. Installation, use and maintenance of the unit must comply with all local and national regulations and European
standards.
Unit assembly
Our product is a heat generator which uses air required for the combustion process directly from the heated environment.
For this reasonand because of basic safety of the user the unit must be installed in adequately ventilated room to ensure continuous flow
of combustion air.
Therefore, it is necessary to arrange connection between the air intake and the external environment (as depicted in Figure 2.1).
Air intakes must have following characteristics:
1.
They must have an internal cross-section of at least 80 cm
2
;
2.
They must be mounted close to the floor level;
3.
They must be adequately protected by wire mash or grate so that the minimum cross-section required for air passage is not reduced;
4.
They must be placed so that they are not blocked in any way.
A proper flow of fresh air can be obtained through the use of an opening into the adjacent room, provided that the room is equipped
with direct ventilation and there is no fire risk as in case of storages, garages or warehouses.
It is recommended to avoid installation of the heat generator in spaces containing devices not operational when isolated from external
environmentor spaces containing devices which could lower the pressure in the roombecause it can cause a weak air flow in our product.
ATTENTION: The discharge of combustion remains into a shared exhaust flue gas pipe.