  ATTENTION: In case the appliance will not be used for a longer period of time (more than 15 days), remove all remaining pellet 

from the hopper to avoid humidity increase which can lead to product malfunction. 

  ATTENTION: Excess humidity of pellet can cause deterioration and create dust, which can lead to increased accumulation in the 

boiler area and even blockthe pellet feed system (auger). 

  When loading the hopper take care not to spill pellets in other interior parts of the product. 

  Use only pellet of 6 to 8 mm diameter. 

 

 

 

General warnings and recommendations 

 

ATTENTION: Carefully read the provided manual before installation. 

 

ATTENTION: The firebox must be emptied before switching on the unitand in case any problems occur when starting the unit. 

  It is absolutely prohibited touse any other solid or liquid fuel except 6 mm diameter wood pellet. Avoid the use of damp or crushed 

pellets. 

  In order to optimize the appliance functionality it is recommended to usewood pellets certified by accredited body. The use of any 

other pellets beside those listed by the manufacturermay result in appliance malfunction and render the warranty void. 

  Do not use this unit as an incineratoror in any other way except the intended. 

 

ATTENTION:  If  you  cannot  ignite  the  stove  you  have  to  empty  the  firebox.  If  not  cleaned,  it  can  cause  an  extremely  strong 

combustion and the creation of large amounts of smoke. 

 

ATTENTION: Do not open the door and do not turn off the power supply during the ignition or extinguishing phase, while the unit 

is operational, even if the combustion chamber is blocked or overloaded. Before dealing with the problem start extinguishing phase and give 
unit time to shut down. Do not try to reignite the unit before solving the problem. 

  ATTENTION: Do not interrupt extinguishing process (for example, by unplugging) until it is over. 

 

ATTENTION: If the wood pellet accumulates in the combustion chamber while the unit is operational, switch off the unit and switch 

it on with the greater ventilation program. If the pellet is still accumulating, try a different pellet or contact the manufacturer’s assistance 
service. 

  Never load pellet into combustion chamber manually. 
  Do not attempt any unauthorized modification of the appliance. 

 

 

INSTALLATION 

 
To successfully install the productand prevent the occurrence of faults you will find a number of simple tips for installation in accordance with 

the relevant applicable regulations. Installation, use and maintenance of the unit must comply with all local and national regulations and European 
standards. 

 

 

Unit assembly 

Our product is a heat generator which uses air required for the combustion process directly from the heated environment. 
For this reasonand because of basic safety of the user the unit must be installed in adequately ventilated room to ensure continuous flow 

of combustion air. 

Therefore, it is necessary to arrange connection between the air intake and the external environment (as depicted in Figure 2.1). 

Air intakes must have following characteristics: 

1. 

They must have an internal cross-section of at least 80 cm

2

2. 

They must be mounted close to the floor level; 

3. 

They must be adequately protected by wire mash or grate so that the minimum cross-section required for air passage is not reduced; 

4. 

They must be placed so that they are not blocked in any way. 

  A proper flow of fresh air can be obtained through the use of an opening into the adjacent room, provided that the room is equipped 

with direct ventilation and there is no fire risk as in case of storages, garages or warehouses. 

It is recommended to avoid installation of the heat generator in spaces containing devices not operational when isolated from external 

environmentor spaces containing devices which could lower the pressure in the roombecause it can cause a weak air flow in our product. 

  ATTENTION: The discharge of combustion remains into a shared exhaust flue gas pipe. 

Summary of Contents for CFH XILA

Page 1: ...METALNA INDUSTRIJA AD 17500 VRANJE SRBIJA Radni ka 1 Tel 017 421 121 INSTALLATION USE AND MAINTAINANCE MANUAL CFH XILA ENG_v 1 0...

Page 2: ...ning or operation should be carried out only by qualified personnel Do not use any flammable liquids for ignition process This unit must not be used by people including children with limited physical...

Page 3: ...devices 10 Control panel 11 KEYS 11 LED 11 DISPLAY 12 MENU 12 User menu 1 13 DISPLAYS 13 SETTING PRODUCT POWER 13 MANUAL PELLET LOAD 13 PELLET FEEDER MODIFICATION 13 COMBUSTION FAN MODIFICATION 14 EN...

Page 4: ...essingin order to optimize the painting process and improve the final result Gaskets which make combustion chamber air impermeable They must be checked periodically to prevent the improper combustion...

Page 5: ...2 TOP A Exhaust gases pipe diameter 80 Dimensionsin mm B 3 4 Unit inflow pipe C 1 Unit return pipe D Air intake 50 Details...

Page 6: ...2 7 Heating power to water kW 14 5 4 7 Heating power to ambience kW 3 5 1 4 Efficiency 93 4 95 7 Emissions of CO with 13 of oxygen 0 0131 0 0074 Combustion gas temperature C 126 67 Gas mass flow g s 1...

Page 7: ...value of this fuel LHV 4100 5000 kcal kg Wood pellet used as fuel must have excellent qualitative characteristics such as defined in standards DIN 51731 ONORM M 7135 and EN plus A1 Example of basic d...

Page 8: ...ood pellet accumulates in the combustion chamber while the unit is operational switch off the unit and switch it on with the greater ventilation program If the pellet is still accumulating try a diffe...

Page 9: ...stancefrom combustible material cm ATTENTION After selection of the unit location it is possible to modify unit s height by tilting it sideways and unscrewing legs to reach the proper space from the b...

Page 10: ...certain number of indications that point out the standard for this type of system configuration Always make sure there is an inspection opening I which will enable regular cleaning activities and remo...

Page 11: ...e separated from the outer part of the chimney Figure 2 6 Exampleconnection to the chimney In case of fire in the chimney or exhaust pipe immediately switch off the unit and disconnect it from the pow...

Page 12: ...onnect the power cable to the household powerline and press ON button on the rear side of the unit At the beginning of use unpleasant fumes and odors may occur originating from painted part These inco...

Page 13: ...repeat the loading of the auger every time the hopper is empty 6 Empty the firebox 7 In order to switch on the stove hold ignition key for a few seconds The stove will initiate the check up and igniti...

Page 14: ...ossible for one or more sensors to be interrupted or short circuited This will be detected during the check up phase The failure of these probes could lead to ignition failure continued state of modul...

Page 15: ...o high temperature of flue gases Er07 Encoder error No signal Er08 Encoder error Unable to adjust number of revolutions Er09 Low water pressure Er10 High water pressure Er11 Error due to problems with...

Page 16: ...St Winter InU mode FC Firmware code and revision FYSD01000114 00 00 product without two way radio FYSD01000102 00 00 product with two way radio 395 Manufacturer production code 0Y 0X N B If the value...

Page 17: ...t value default value is 0 After 3 seconds value is stored and the display returns to normal ENABLING CHRONO FUNCTION This sub menu allows activation deactivationof chromo programmingmode Press and ho...

Page 18: ...y for the technical assistance network LEAr Remote control code learning menu Only if the product has two way radio option User menu 2 settingsare shown in the upper display Press K1 key to exit User...

Page 19: ...reach wanted sub menuand pressK5key Gio r n 2 PressK3 K7 keys to select one of three possible programming options _ _ _ _ 1I Mo 3 Press and holdK4 key for3 seconds 00 00 1 Mo 4 Choose the start up tim...

Page 20: ...turn toUser menu 2 settings pressK1key SYSTEM MENU This menu allows access toSystem menu The upper display showstPAr ATTENTION This menu cannot be accessed because it is only for the technical assista...

Page 21: ...ply Preporu uje se da o istite zone opisane iznad pomo u etke koju dobijete sa ure ajem ili usisiva a PA NJA na svakih 3 4 dana obavezno o istite dimne cevi u kotlu Otvorite vrata komore i specijalnom...

Page 22: ...in two ways switching off the rear side power keyor pulling out the power cord from the socket either the wall socket or stove rear side connection plug In case the maintenance operations described i...

Page 23: ...and reset timers by unscrewingtwospark plugs at the back of the unitand pressing both buttons Check air intake opening for blockages Too high environment temperature insufficient temperature reduction...

Page 24: ...ine to shut down and then press and hold ON key for 3 seconds Check the water pressure level in the system Faulty probe Contact service Er11 Clock error Problemswith the internal clock Press and hold...

Page 25: ...t down and then press and hold ON key for 3 seconds Check the primary air openings Check soiling and draft of flue gas pipe Contact service ATTENTION If the recommended solutions fail to remove the pr...

Page 26: ...the content of this Manual Any complete or partial reproduction of the Manual without the Company s written approval is strictly forbidden Offenders will be prosecuted All data and measures are provid...

Reviews: