Technical Manual
– Color Tester
40
TROUBLE SHOOTING
EN
ERROR
CODES
ERROR
DETECTED
ERROR
DESCRIPTION
TROUBLESHOOTING
240
MANUAL_INTERVENTION_REQUEST0
At the end of X Axis movement
in Capping the photocell is NOT
engaged
Operator's intervention required
241
MANUAL_INTERVENTION_REQUEST1
Can not detected at the end of
Dispensing, or at the beginning
of Capping, or at the end of
Capping
Operator's intervention required
242
MANUAL_INTERVENTION_REQUEST2
Can not detected at the end of
Capping
Operator's intervention required
301-308
B”X”_BASE_RESET_ERROR, where “X” =
1..8
"X" BASE slave reset procedure
duration time-out
Verify the cleanliness and positioning of the
photocell mounted on the ”X” BASE, then
clean or reattach the sensor. Verify the
integrity
of the “flag”, the pusher, the motor,
and the connectors, and replace the parts
or the entire unit if any mechanical wear or
damage is found. If the communication is
present but an electronic type problem
remains, replace the SCCB board.
309-332
C”X”_COLOR_RESET_ERROR, where
“X”=1..24
"X" COLORANT slave reset
procedure duration time-out
Verify the cleanliness and positioning of the
photocell mounted on the ”X” COLORANT,
then clean or reattach the sensor. Verify
the integrity of the “flag”, the pusher, the
motor, and the connectors, and replace the
parts or the entire unit if any mechanical
wear or damage is found. If the
communication is present but an electronic
type problem remains, replace the SCCB
board.
333
MOVE_X_AXIS_RESET_ERROR
Slave X AXIS reset procedure
duration time-out
Verify the cleanliness and positioning of the
photocells of X axis, then clean or refix the
sensor. Verify the integrity of the motor and
the connectors, and replace the parts or
the entire unit if any mechanical wear or
damage is found. If the communication is
present but a problem of an electronic type
remains, replace the SCCB board.
334
MOVE_Y_AXIS_RESET_ERROR
Slave Y AXIS reset procedure
duration time-out
Verify the cleanliness and positioning of the
photocells of Y axis, then clean or refix the
sensor. Verify the integrity of the motor and
the connectors, and replace the parts or
the entire unit if any mechanical wear or
damage is found. If the communication is
present but a problem of an electronic type
remains, replace the SCCB board.
Summary of Contents for Color Tester
Page 26: ...Technical Manual Color Tester 26 CONNECTION DIAGRAMS EN 8 CONNECTION DIAGRAMS...
Page 27: ...Technical Manual Color Tester EN TROUBLE SHOOTING 27...
Page 28: ...Technical Manual Color Tester 28 CONNECTION DIAGRAMS EN...
Page 29: ...Technical Manual Color Tester EN TROUBLE SHOOTING 29...
Page 30: ...Technical Manual Color Tester 30 CONNECTION DIAGRAMS EN...
Page 31: ...Technical Manual Color Tester EN TROUBLE SHOOTING 31...
Page 32: ...Technical Manual Color Tester 32 CONNECTION DIAGRAMS EN...
Page 33: ...Technical Manual Color Tester EN TROUBLE SHOOTING 33...
Page 34: ...Technical Manual Color Tester 34 CONNECTION DIAGRAMS EN...
Page 44: ...Technical Manual Color Tester 44 TROUBLE SHOOTING EN Page left intentionally blank...