Page 18
Instruction Manual, SSB Retractor - Mini Retract-A-Ball
Standard machines and machines delivered with ATEX certification
in accordance with Directive 94/9/EC
IM-TE91A901-EN1
Installation
(continued)
Special Conditions for Safe Use in accordance with the ATEX Certification,
Directive 94/9/EC –(c
ontinued)
Temperature
ATEX
Warning:
Atmosphere/surface temperature:
In potentially explosive atmospheres, the temperature must not exceed the maximum
surface temperature according to the temperature class for the combustible gas or
liquid.
ATEX
Warning:
Steam cleaning:
Tanks with capacities greater than 100 m
3
that could contain a flammable atmosphere
should not be steam cleaned, as steam issuing from a nozzle could contain charged
droplets.
Tanks smaller than this may be steam cleaned providing that: the steam nozzles and
other metal parts of the system are reliably earthed and grounded to the tank
structure.
Pressure
Avoid hydraulic shocks. Increase pressure gradually. Do not exceed 4 bar inlet pressure.
Recommended inlet pressure: 2-4 bar. High pressure in combination with high flow rate will increase
consumption of wear parts. High pressure will also reduce the cleaning effect.
ATEX
Warning:
Steam cleaning pressure:
If stream cleaning is done through the machine, the steam pressure must not cause
the machine to rotate.
ATEX
Warning:
Draining:
If the machine is drained using compressed air, then the compressed air pressure
must not cause the machine to rotate.