5
Check the position of the tensioning element:
the tensioning element has to lie on the
distance sleeve and inner rotor.
Otherwise loosen the screws again and re-
align the tensioning element.
6
If the position is correct, first tighten the
screws of the tensioning element with half the
tightening torque crosswise.
Subsequently tighten them several times
crosswise with the
full
tightening torque until
no screw can be turned any further.
NOTE
The screws are only tightened correctly
when they can no longer be turned while
being tightened with the full torque.
7
Press the containment can
038
with the
centring flange
110
onto the pump flange and
tighten the connecting screws
914.6
,
200007725-1-EN-GB