8.5 Removing the pump
Recommendations:
• Vessels for leaking pumped liquid
DANGER
Risk of death resulting from electric shock
.
• Ensure that the power supply is disconnected.
• The motor may only be separated from the power supply by an authorized
electrician.
WARNING
Risk of injury through emitted hot, poisonous or corrosive pumped liquid
.
• Wear protective clothing during all the work.
• Before carrying out work let the pump cool down to the ambient
temperature.
• Ensure that the pump is depressurized.
• Collect the pumped liquid safely and dispose of it in an environmentally
compatible manner.
1.
Disconnect the motors from the power supply and secure them against
being switched back on.
2.
Close the pressure-side and suction-side shut-off devices.
3.
Empty the pump at the lower point using the draining plug. Collect the
emitted pumped liquid in a suitable vessel
4.
Loosen the connecting flanges.
5.
Loosen the fastening of the pump unit on the mounting surface and
dismantle the motor and pump bracket.
200007725-1-EN-GB
37
Installation, removal and connection 8
EN
Summary of Contents for ALP 100
Page 6: ......
Page 8: ...200007725 1 EN GB 8 1 Warning signs in text EN Safety...
Page 10: ...200007725 1 EN GB 10 2 About this document EN...
Page 14: ...200007725 1 EN GB 14 3 Safety EN Safety...
Page 21: ...200007725 1 EN GB 21 Technical data 5 EN...
Page 24: ...200007725 1 EN GB 24 5 Technical data EN...
Page 32: ...200007725 1 EN GB 32 7 Transportation Storage and Disposal EN...
Page 38: ...200007725 1 EN GB 38 8 Installation removal and connection EN...
Page 66: ...200007725 1 EN GB 66 11 Troubleshooting EN...
Page 72: ...200007725 1 EN GB 72 12 Spare Parts EN...
Page 77: ...14 EC Declaration of conformity 200007725 1 EN GB 77 EN...