9.7 Taking pump out of operation
WARNING
Risk of injury or poisoning through emitted pumped liquid
.
• Wear protective clothing during all the work.
• Collect the emitted pumped liquid safely and dispose of it in an
environmentally compatible manner.
• Carry out the following measures during shutdowns:
Table 13: Measures for operation interruption
Pump is
Measure
• Shut down for longer period
Depending on the pumped liquid.
• Drained
Close the pressure-side and suction-side stopcocks.
• Dismantled
Disconnect the motors from the power supply and secure them
against being switched back on.
• Stored
Observe measures for storing & preservation; refer to
.
Table 14: Measures depending on behaviour of the pumped liquid
Behaviour of the pumped liquid
Duration of the shut down
Short
Long
• Sediment solids
− Rinse the pump.
− Rinse the pump.
• Congealed/frozen
• No corrosive burden
− Heat or drain the pump.
− Drain the pump.
• Congealed/frozen
• Corrosive burden
− Heat or drain the pump.
− Drain the pump.
− Preserve the pump.
• Remains liquid
• No corrosive burden
-
-
• Remains liquid
• Corrosive burden
-
− Drain the pump.
− Preserve the pump.
• Drain the pump via the pressure and suction line and vent screw.
200007725-1-EN-GB
45
Operation 9
EN
Summary of Contents for ALP 100
Page 6: ......
Page 8: ...200007725 1 EN GB 8 1 Warning signs in text EN Safety...
Page 10: ...200007725 1 EN GB 10 2 About this document EN...
Page 14: ...200007725 1 EN GB 14 3 Safety EN Safety...
Page 21: ...200007725 1 EN GB 21 Technical data 5 EN...
Page 24: ...200007725 1 EN GB 24 5 Technical data EN...
Page 32: ...200007725 1 EN GB 32 7 Transportation Storage and Disposal EN...
Page 38: ...200007725 1 EN GB 38 8 Installation removal and connection EN...
Page 66: ...200007725 1 EN GB 66 11 Troubleshooting EN...
Page 72: ...200007725 1 EN GB 72 12 Spare Parts EN...
Page 77: ...14 EC Declaration of conformity 200007725 1 EN GB 77 EN...