3.3 Safety instructions for magnetic coupling systems.
Magnetic fields from magnetic coupling systems (MCS) can influence the
function and operational safety of electrical and electronic devices.
NOTE
The following safety instructions must be observed.
Additional safety instructions for magnetic coupling systems.
• Keep the MCS away from pacemakers. There is a danger to life!.
• Under no circumstances may persons with pacemakers perform
installation, dismantling or maintenance work.
• Persons with pacemakers must comply with the following safe distances to
the MCS:
• 3 m distance to the openly accessible MCS.
• 1 m distance to pump units with installed MCS.
• Do not bring the MCS in the immediate area of PCs, data carriers and other
electronic components.
• Keep the MCS away from clocks, magnetized tools and measuring
equipment as well as all magnetizable parts.
• Do not bring both the MCS parts together, as this can destroy the magnetic
coupling system.
200007725-1-EN-GB
13
Safety 3
EN
Safety
Summary of Contents for ALP 100
Page 6: ......
Page 8: ...200007725 1 EN GB 8 1 Warning signs in text EN Safety...
Page 10: ...200007725 1 EN GB 10 2 About this document EN...
Page 14: ...200007725 1 EN GB 14 3 Safety EN Safety...
Page 21: ...200007725 1 EN GB 21 Technical data 5 EN...
Page 24: ...200007725 1 EN GB 24 5 Technical data EN...
Page 32: ...200007725 1 EN GB 32 7 Transportation Storage and Disposal EN...
Page 38: ...200007725 1 EN GB 38 8 Installation removal and connection EN...
Page 66: ...200007725 1 EN GB 66 11 Troubleshooting EN...
Page 72: ...200007725 1 EN GB 72 12 Spare Parts EN...
Page 77: ...14 EC Declaration of conformity 200007725 1 EN GB 77 EN...