17/23
ALFA IN a.s. ©
www.alfain.eu
Amperage setting (SYN)
Wire speed setting
No symbol
Material thickness setting (SYN)
Voltage setting (MAN)
Correction (SYN)
Symbols on the torch display
H2
J.xx
JOBs (xx – JOB No)
I.xx
Choke level (SYN/MAN).
(Only with firmware 2015 and newer)
ELE
Machine is in MMA (Electrode) mode
RESET
1. Pressing
A8
+
A19
at the same time more than 3 s makes RESET – default
parameters will be restored.
2. It will delete saved JOBs!
8. MIG/MAG WELDING SYNERGY
1. Choose SYN method (see
SETTING THE METHOD OF WELDING
)
2. Left display
A10
shows SYN, right display
A11
shows the number of
synergistic curve.
3. Selects synergic curve (program number) using encoder
A16
according to
the table, which is located inside. To confirm the program number press
the encoder
A5
.
Picture
9 –
Table of synergic curves
4. Use
A8
button to select the values you want to set the machine with, the
corresponding light will illuminate.