6/24
ALFA IN a.s. ©
www.alfain.eu
4
TECHNICAL DATA
Technical data
AXE 250
AXE 320
Method
MIG/MAG MMA MIG/MAG MMA
Mains voltage
V/Hz
3 x 400/50-60
3 x 400/50-60
Mains protection
A
16 @
16 @
Max. mains current I1
A
16,4
18,2
23,4
22,9
Max. effective current I
1eff
A
12,9
13,0
12,9
12,8
The range of welding. current
A
20-250
30-250
20-315
30-300
Open circuit voltage U
20
V
54,4
63,1
Welding current (DZ=100%) I
2
A
210
190
210
190
Welding current (DZ=60%) I
2
A
250
230
250
230
Welding current (DZ=x%) I
2
A
60%=2
50
60%=2
50
25%=3
15
15%=3
00
Protection
IP 23S
Standards
EN 60974-1, EN 60974-10 cl. A
Dimensions (w x d x h)
mm
474 x 911 x 670
Weight
kg
47,6
Wire feed speed
m/min 0,5 - 17
---
0,5 - 17
---
Spool diameter
mm
300
---
300
---
Spool Weight
kg
18
---
18
---
S
The machine marked with this symbol can be used for welding in areas with
an increased risk of electric shock.
The machine structure is designed so that, in any case, even if the failure rectifier
does not exceed the permitted peak value of the open circuit voltage
according
to EN 60974-1, i.e., 113 V direct current or 68 V alternating.