- 7 -
ALFA IN a.s. ©
www.alfain.eu
•
Computers, robots, electro-medical instruments and life-support
systems.
•
Radio-television transmitters and receivers.
•
Pacemakers and hearing aids.
•
All very sensitive electrical equipment.
The operator is responsible for the installation and use of the cutting
machine. If there should be any fault in operations of other systems located
in the immediate vicinity of the generator, we recommend suspending
operations and consulting the manufacturers.
2.2 PROTECTIVE UTTILITIES
•
Welding helmet with filter shade at least 10
•
Welding gloves
•
Welding apron and cloth
•
Welding boots
2.3 RISK OVERVIEW
•
Risk of electric shock.
•
Ultraviolet light and light radiation
•
Risk of inhaling gas fumes and dust particles
•
Burns
•
Noise
NOTE
•
It is forbidden to operate a machine with damaged insulation of the
welding torch or supply cable.
•
Never operate the machine taken down or damaged covers.
•
It is forbidden to operate the machine in wet environments and
outdoors in rain or snow.
•
Ensure proper grounding clamping pliers, which also reduces the risk
of electric shock.
•
Use prescribed protective utilities, keep them dry.
•
Arc welding produces intense electric and magnetic emissions that
may interfere with the proper function of cardiac pacemakers, hearing
aids, or other electronic health equipment. Persons who work near
plasma arc cutting applications should consult their medical health
professional and the manufacturer of the health equipment to
determine whether a hazard exists.
•
Never aim the torch against the eyes, body or other person.