- 15 -
ALFA IN a.s. ©
www.alfain.eu
X5
Button
•
In MANUAL disabled
•
In SYNERGY switches among A, wire speed or
material thickness
•
Enters secondary parameters (together with
button X3)
X6
Green LED – lights if on the display X8 are displayed
Amperes (required setting), (just SYNERGY).
X7
Green LED - lights if on the display X8 is displayed
Wire Speed in m/min (required setting), (just
SYNERGY).
X8
Left Display X8, shows:
•
Amperage (real or required)
•
Wire speed
•
Material thickness
•
Program No
•
Secondary parameters:
- ISP – initial speed (soft start) [%]
- PrG – Pre gas time [s]
- PoG – Post gas time [s]
- brn – Burn back time [s]
- SPo – Time of tack welding [s]
- Int - Time of interval [s]
X9
LED - Cooling circuit error
X10
LED - Lights after finishing welding and signals the
HOLD function of A+V (last measured parameters)
X11
LED - Thermal overheating. Leave the machine on to
cool down by means of the fans.
X12
Right Display
•
Voltage (real)
•
Values of the secondary parameters
•
Switches and choke settings (Just SYNERGY)
X13
Position of the coarse switch (just SYNERGY)
X14
Position of the smooth switch (just SYNERGY)
X15
Position of the choke (just SYNERGY)
X16
LED – The mode of selecting the program is active
(just SYNERGY).
X17
Green LED – lights if on the display X8 is displayed
material thickness, (just SYNERGY).