background image

Using Andromeda 

-The Andromeda behaves as a monotimbral synth 
in Program mode, while splits, layers, and multichannel 
operation is accessed in Mix mode.  
-The majority of front-panel functions are per Program, 
excepting the Master Volume control and Master Tune 
control. Everything you see is stored per Program, and 
can be edited in the same way in Mix mode, per Mix 
Channel.  
-Moving any control (excepting the 'Soft Pots' under the 
display) will cause the associated graphic page to load in 
the display. Press each module's View button to access 
these pages without moving a knob (and thus disturbing 
a parameter setting). Some modules, such as the Envelope 
and Oscillator modules have more than one page; in the 
Display, you will notice that the lowest row of text represents 
what the Soft Buttons access, and the row of text above that, 
what the Soft Pots do. Multiple pages can be accessed via the 
Soft Buttons.  
-If you wish to turn more than one knob at a time or simply 
retain a single graphic page in the display, please press 
Soft Buttons 7 and 8 simultaneously to lock the display to the 
current page. It is fully possible to turn multiple pots simultaneously and not 
adversely the unit.  
-The Increment and Decrement keys to the right of the  
Display are useful in a number of ways. You will notice that 
most parameters have fractional values, meaning that they 
have much greater resolution than 1->127 or so. The keys 
can be used to zero in on, or “snap-to” precise values. Simultaneously  
pressing the Inc/Dec keys will set the selected parameter  
to zero, or in the case of certain parameters, to its most useful  
setting (Filter 2 Key Track will be set to exactly 100%, which is perfect keyboard 
tracking; Pulse Width will be set to  
exactly 50%, etc.) Holding one of these keys will cause the  
selected parameter value to begin to scroll. Don’t be surprised if you press Inc or 
Dec and don’t notice an instant visual change in the parameter value; the 
fractionally-based parameters have more resolution than the display can reflect 
in using five digits, and you may find two or three clicks are required to notice 
movement in the numeric values.  
-The potentiometers can be set to Jump-To whatever position 
they are when you touch them, or to Pass-Through, meaning 
that a pot won't become active until you move it past the 
stored value for that pot. If a stored pot value is 0 or 100, 
you will have to turn the pot all the way to that relative point to enable it. To select 
between these choices, press the Global button, and then press soft button five 
(“Panel” is the parameter in the display). Soft pots one and two are then used 
select the various modes that are available. 

Summary of Contents for ANDROMEDA A6

Page 1: ...rs etc PROGRAM MODE FRONT PANEL MODULES Defining each section of the front panel and some tips on using each Keyboard performance parameters LFOs Sample and Hold Process Audio Rate FM Oscillators and...

Page 2: ...faster envelope response times than previous versions but at the cost of a bit of zipper noise in the parameters VCAs and with large pitch modulations On the Filt VCA chip this allows for faster ampli...

Page 3: ...nd followthe prompts This will clear the tuning tables and the ribbon calibration as well you should Autotune after a Soft Reset the instrument should be warmed up already If this doesn t work try pow...

Page 4: ...ght of the Display are useful in a number of ways You will notice that most parameters have fractional values meaning that they have much greater resolution than 1 127 or so The keys can be used to ze...

Page 5: ...place of the hardware required on other analog synthesizers which require occasional calibration and over time possible replacement After the above tune the unit again after about five minutes All sho...

Page 6: ...with a Trigger Page LFOs S H Envelopes Seq Arp etc can either be caused to advance a single increment begin running or reset LFO Phase whenever the selected Source any Source whether it s a Clock or n...

Page 7: ...s In this case the LFO to Oscillator pitch routing s overall amount has the Mod Wheel assigned to control it Any controller Envelope LFO velocity etc may be assigned Sample and Hold A module that memo...

Page 8: ...nd the output VCAs The Fastest setting will allow for sharper percussion sounds especially the type produced by analog drum machines and popularized by Kraftwerk etc I ve noted in creating a Minimoog...

Page 9: ...oice and uses the summed outputs of the Oscillators Suboctaves as the inputs the Analog Noise or External Inputs and a modest Filter Feedback which basically squares signals up it doesn t punch like t...

Page 10: ...1 s LP and HP outputs are again live on the Post Filter Mix module in parallel to the output of Filter 2 4 The output of the Pre Filter Mix module is sent into Filter 1 only Nothing is fed into the in...

Page 11: ...remain active even if you set them to their minimum setting This of course allows you to use the controls as if it were a typical analog hardware Envelope which is especially comfortable if you enjoy...

Page 12: ...will occur from none once to 240 times before it stops looping Beyond 240 are the Sustain and Infinite settings In Sustain it will loop as long as a note is held Available Types are Forward Backward...

Page 13: ...y sending each Individual Output to an external mixer and panning them individually The signals will be output depending upon the Keyboard Mode assignment From the A6 manual Page 59 LOWEST This will a...

Page 14: ...ogram if you are on a page that is directly related to the Program if you see Mix level parameters in the display and press Store you will see a prompt relating to Storing the Mix You may solo a Mix C...

Page 15: ...Bank numbers 120 through 123 inclusive take advantage of this path Be sure to play across the keyboard as the filters are set to track the keyboard in the same manner as with the factory Program 045...

Page 16: ...e input amount to best function with your external gear To set up continuous Oscillator modulation Press the OSC button in the External Inputs section Select a Mod in the target oscillator and select...

Page 17: ...each note but the phase will be free running If VOXTRG ON TRIG and TRIG ON and Freerun OFF then the Clock will start upon the first received Trigger from the Mod Add Freerun and the LFO will start cl...

Page 18: ...an Envelope simply set the Source to that LFO in the Trig and ReTrig pages and set the Level and Polarity the same on each page or differently Note Only one Trigger Mode is allowed it is global for T...