background image

Aleis ISO-FFW  Series Operational Manual 

 

 

 

 

Aleis Pty Ltd 

ACN 130 754 826 

www.aleis.com   Ph: 07 46685942 

 

 
 
 

       
 

Reader 

User Guide 

ISO-FFW Series Reader 

 
 
 

ISO-FFW-6000            

 

Standard unit with Read and On LEDs Only 

 
ISO-FFW-8030 

 

 

Display and 8030 Keypad 

ISO-FFW-8030-EXP       

 

With 9000 expansion board fitted 

ISO-FFW-8030- EXP-CLK         

With 9000 expansion board and Clock fitted 

 
ISO-FFW-9060 

 

 

Display and 9060 Data Entry Keypad 

ISO-FFW-9060EXP       

 

With 9000 expansion board fitted 

ISO-FFW-9060- EXP-CLK  

With 9000 expansion board and Clock fitted 

 

 
 

Version 1.00 

07/03/2011 

 

IMPORTANT! 

This User Guide must be read in conjunction with Reader, prior to use. 

 

Copyright Aleis Pty Ltd 2011 

 
 
 
 
 
                                                                        A1064AUS 
 
 

Summary of Contents for ISO-FFW-6000

Page 1: ...Keypad ISO FFW 8030 EXP With 9000 expansion board fitted ISO FFW 8030 EXP CLK With 9000 expansion board and Clock fitted ISO FFW 9060 Display and 9060 Data Entry Keypad ISO FFW 9060EXP With 9000 expan...

Page 2: ...e Reader 11 9 6 Formatting the File System 13 9 7 How to Format your reader 13 10 0 ISO FFW8030 Menu Tree 14 10 1 Session Menu 14 10 2 Read Setup Menu 15 10 3 System Setup Menu 16 10 4 Reader Informat...

Page 3: ...9060 Audio and Visual alerts 37 17 0 ISO FFW9060 Menu 38 17 1 Session 38 17 11 New 38 17 12 Data Entry Setup 38 17 13 Data Entry Locking 38 17 14 Templates 38 17 15 Send to PC 38 17 16 Clear 38 17 17...

Page 4: ...ceiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modification warning F...

Page 5: ...the antenna reader and software 1 WARNING All Aleis warranties will be immediately voided if this reader is used in any way with Hyperterminal 2 Have only one system at a time switched on unless Maste...

Page 6: ...0 Standard unit with Read and On LEDs Only ISO FFW 8030 Display and 8030 Keypad ISO FFW 8030 EXP With 9000 expansion board fitted ISO FFW 8030 EXP CLK With 9000 expansion board and Clock fitted ISO FF...

Page 7: ...connectors into place 3 0 WARNINGS Never open the reader box Never drill the antenna Some magnetic fields will affect reading such as some computers computer monitors electric motors and generators Th...

Page 8: ...puter The ISO FFW Series Reader can also link directly with your computer The Aleis ISO FFW Series Reader is compatible with all major herd management programs accepting a standard real time RFID from...

Page 9: ...d linear power supply DO NOT USE A SWITCH MODE POWER SUPPLY The power supply must be approved for use in your country and meet all your countries emission requirements 8 0 THE ISO FFW8030 KEYPAD 9 0 I...

Page 10: ...up of cattle 9 3 How to Create Sessions using F1 and F2 Keys 1 Press F2 to end current session 2 Press F1 to start new session Four Beeps will be heard Note you can start a new session even if the one...

Page 11: ...the main screen of Aleis DataLink where the session names and numbers are normally displayed 5 Click on that file name 6 Now click on the Upload button located at the left side of the DataLink screen...

Page 12: ...tton 18 Scroll down to Duration and press the OK button 19 Choose the setting you want and press the OK button Until Keypress means that the reader will continue to beep and flash the LEDs until any k...

Page 13: ...ne the data then is lost Formatting of the file system should be done every 2 4 months for heavy users or 4 6 months for light users Before formatting the file system make sure you have saved any data...

Page 14: ...FFW Series Operational Manual 14 of 45 10 0 ISO FFW8030 MENU TREE The readers menu has 5 main menu and several sub menu items Session Read Setup System Setup Reader Information Memory Status 10 1 Ses...

Page 15: ...Aleis ISO FFW Series Operational Manual 15 of 45 10 2 Read Setup Menu...

Page 16: ...Aleis ISO FFW Series Operational Manual 16 of 45 10 3 System Setup Menu...

Page 17: ...Aleis ISO FFW Series Operational Manual 17 of 45 10 4 Reader Information Menu 10 5 Memory Status Menu...

Page 18: ...t of screen will increase READ and STORED LED s blink once No ID Read One long beep after read on time out NO RFID READ No RF Signal being received Two very quick beeps every 30 seconds Flashing Batte...

Page 19: ...ares RFIDs read with Current Session Session Select which session number you want to compare RFID s with 12 23 Alert Alert Options The Condition Sets the alert condition when a RFID is read There are...

Page 20: ...the serial output only 9600 38400 57600 115200 BlueTooth Config Mode Off On Tag Format Set the lentgh of the RFID string ISO 26 Digit ISO 27 Digit 15 Digit 16 Digit Scale Interface Sets scale type ov...

Page 21: ...faults back to factory settings 8030 50 Series 9030 50 60 Series 12 37 Set Date Time Sets Date and Time 12 38 RFM Settings FDX HDX Mode Sets the readers FDX HDX mode FDX HDX With Boost FDX Only HDX On...

Page 22: ...s for technical assistance only product identification Reader Info Hardware Hardware Version Software Software Version Date Software Date Serial No Reader Serial Number Reader Type Aleis Reader Model...

Page 23: ...Aleis ISO FFW Series Operational Manual Page 23 of 45 13 0 THE ISO FFW9060 QWERTY KEYPAD Data Entry Keys Function Keys Directional Keys Menu Keys...

Page 24: ...ion 1 To start a new session and read another group of animals press MENU 2 Select Session press OK 3 New will be highlighted press OK 4 To read next group of cattle same as last group of cattle press...

Page 25: ...cluding the last line Field Default Data TAG WGT P E PAD River 10 When finished press C located to left of MENU button to return to session screen 11 Read first RFID device press F4 12 Type in data re...

Page 26: ...and print with the report There are five templates available and four fields available per template 6 Field column allows for three letters numbers only for each field If recording information for a t...

Page 27: ...ering data These should always be locked with an X This sho DEF If X is in box locks default data created in Data Entry Setup Default Data is any data that will be the same for every animal read DATA...

Page 28: ...plate as per these instructions make all the changes go to Save Template and highlight template being updated Press OK and reader will overwrite replace it with new updated template Remove Template In...

Page 29: ...eader ON 2 Assuming previous session is finished Press MENU 3 Session will be highlighted press OK 4 Press down arrow until Templates is highlighted 5 Press OK 6 Press down arrow until Default Templat...

Page 30: ...er 5 A working COM port you can check this by turning your 9060 reader on and then opening Aleis DataLink Down the bottom right corner of the Aleis DataLink screen you should see that the software has...

Page 31: ...OK button 29 Scroll back to the name you saved the uploaded file as and press the OK button 30 Press the C button located beside the MENU button 31 The reader will then reboot now press the MENU butto...

Page 32: ...done the data then is lost Formatting of the file system should be done every 2 4 months for Heavy users or 4 6 months for light users Before formatting the file system make sure you have saved any d...

Page 33: ...W Series Operational Manual Page 33 of 45 15 0 ISO FFW9060 MENU TREE The readers menu has 5 main menu and several sub menu items Session Read Setup System Setup Reader Information Memory Status 15 1 S...

Page 34: ...Aleis ISO FFW Series Operational Manual Page 34 of 45 15 2 Read Setup Menu...

Page 35: ...Aleis ISO FFW Series Operational Manual Page 35 of 45 15 3 System Setup Menu...

Page 36: ...Aleis ISO FFW Series Operational Manual Page 36 of 45 15 4 Reader Information Menu 15 5 Memory Status Menu...

Page 37: ...of screen will increase READ and STORED LEDs blink once No ID Read One long beep after read on time out NO RFID READ No RF Signal being received Two very quick beeps every 30 seconds Flashing Battery...

Page 38: ...17 16 Clear Clears the readers memory There are two options Current Session All Sessions 17 17 Change Name Changes Sessions Name 17 18 Select Selects the session on the reader Any RFIDs read will be...

Page 39: ...re 5 options On Read On Read No Duplicates On Match On No Match No Alert 17 25 Send Sets the Send Condition when a RFID is read There are 4 options On Read On Match On No Match No Send 17 3 System Set...

Page 40: ...on below Backlight Mode Sets the condition when the Backlight comes on Off On key press On low light Always On LCD Contrast Select required contrast Eg 90 light contrast 120 very dark Subject to viewi...

Page 41: ...to suit the read requirement either for a maximum voltage maximum range or detune for a smaller read distance Sync Mode Sets read cycle synchronization mode Wired requires the TXS orange signal wires...

Page 42: ...e on ISO FFW Antenna Tuning Auto or Manual Manual Tuning not available on ISO FFW User Options Via Keypad or RS 232 Serial Battery Power 12 14 Volt DC Physical Wand Length Wand 300mm Standard other le...

Page 43: ...act of sale of the goods Where specifications drawings or other particulars are supplied by purchaser vendor s price is made on estimates of quantities required Should there be any adjustments in quan...

Page 44: ...equal to 1 the cost of replacing the goods 2 the cost of obtaining equivalent goods or 3 the cost of having the goods repaired whichever is the lowest amount 14 Unless otherwise stated all prices quo...

Page 45: ...property referred to in Section 262 i of the Corporations Law and as a separate charge charges all his other property with the payment of all monies now or in the future becoming owing hereunder prov...