28
8.2. InspirAIR
®
Top 450
Supplier brand
Aldes
Aldes
Aldes
Designation
InspirAIR
®
Top 450
Classic
InspirAIR
®
Top 450
Premium
InspirAIR
®
Top 450
PREMIUM ERV
References
11023476
11023478
11023478
Energy class - Average climate
A
A
B
Average climate - SEC - Specific energy consumption (kWh/(m
2
a)
-36,70
-36,03
-32,10
Cold climate - SEC - Specific energy consumption (kWh/(m
2
a)
-74,37
-74,16
-66,88
Warm climate - SEC - Specific energy consumption (kWh/(m
2
a)
-12,49
-11,55
-9,55
Declared type
RVU
RVU
RVU
Type of airflow
Bidirectional ventilation
unit
Bidirectional ventilation
unit
Bidirectional ventilation
unit
Type of motor installed or planned
4/ Variable speed
4/ Variable speed
4/ Variable speed
Type of heat recovery system
Recuperation
Recuperation
Recuperation
Thermal efficiency of heat recovery (%)
88
89
78
Maximum RVU (m
3
/h)
470
470
480
Electric power absorbed at Qmax (W)
218
244
255
LwA - Sound power level (dB)
57
53
53
Reference airflow (m
3
/s)
0,091
0,091
0,088
Difference in reference pressure (Pa)
50
50
50
SPI (W/(m
3
/h)
0,25
0,29
0,30
Control factor (%)
1
1
1
Type of control system
Manual control
Manual control
Manual control
Maximum declared internal leakage rate under negative
pressure for BVU (%)
1
1
1
Maximum declared external leakage rate under negative
pressure for UVU and BVU (%)
1
1
1
Maximum declared internal leakage rate under positive pressure
for BVU (%)
0,5
0,5
0,5
Maximum declared external leakage rate under positive pressure
for UVU and BVU (%)
0,6
0,6
0,6
Mixing rate for standalone BVU without branch connections (%)
NA
NA
NA
Position of visual alarm
cf. notice
cf. notice
cf. notice
Description of visual alarm
cf. notice
cf. notice
cf. notice
Regular replacement of filters to ensure unit performance and
energy efficiency
cf. notice
cf. notice
cf. notice
Instructions for installation of fresh air inlets
NA
NA
NA
Sensitivity of airflow to pressure variations at +20 Pa
NA
NA
NA
Sensitivity of airflow to pressure variations at -20 Pa
NA
NA
NA
Indoor/outdoor air tightness (m
3
/h)
NA
NA
NA
Annual electricity consumption - AEC (kWh electricity/a)
333
379
396
Average climate - AHS - Annual heating savings (kWh primary
energy/a)
4502
4550
4200
Cold climate - AHS - Annual heating savings (kWh primary
energy/a year)
8808
8901
8216
Warm climate - AHS - Annual heating savings (kWh primary
energy/a year)
2036
2057
1899