Monitoring Chassis Power
Chassis and Power Supplies
page 2-20
OmniSwitch 7700/7800 Hardware Users Guide
April 2005
Note.
If a module of the same type is already installed in the chassis, you can use the
show ni
command to
determine the power requirements for the module to be added. For example, if an OS7-ENI-C24 is to be
added to the chassis, and there is already an OS7-ENI-C24 installed at slot 13, enter the following
command:
-> show module long 13
Module in slot 13
Model Name: OS7-ENI-C24 ,
Description: 24pt 10/100 Mod,
Part Number: 901765-10,
Hardware Revision: 413,
Serial Number: 1453410A,
Manufacture Date: MAY 16 2002,
Firmware Version: 5,
Admin Status: POWER ON,
Operational Status: UP,
Power Consumption: 44,
Power Control Checksum: 0x808,
MAC Address: 00:d0:95:6b:0b:30,
ASIC - Physical: 0x1901 0x0201 0x0201 0x001e 0x001e 0x001e
Note that the module’s power requirement is 44 watts, as shown in the “Power Consumption” field.