GNI Modules
Network Interface (NI) Modules
page 5-18
OmniSwitch 7700/7800 Hardware Users Guide
April 2005
Removing MiniGBIC Connectors
MiniGBICs modules can be hot swapped. You are not required to power off the switch before removing a
MiniGBIC from an OS7-GNI-U12 module. To remove a Miniature Gigabit Interface Converters (Mini-
GBIC) follow the steps below.
Note.
Before handling any components, free yourself of static by wearing a grounding strap, or by ground-
ing yourself properly. Static discharge can damage the MiniGBIC, as well as the Gigabit Ethernet fiber
module. Refer to
“Using the Grounding Wrist Strap and Chassis Grounding Lug” on page 5-24
for more
information.
1
Remove any LC cables from the MiniGBIC.
2
To remove a MiniGBIC you must first open the MiniGBIC’s hinged face to approximately ninety
degrees. Then, grasp the hinged face and carefully pull the MiniGBIC straight out of the slot.
3
Slide the MiniGBIC out of the OS7-GNI-U12’s port.
4
Store the MiniGBIC in a secure, static-free location. Placing the MiniGBIC in an anti-static bag is
recommended.