Optical X6STM1 option card test
Overview
This test verifies whether the installation of the optical STM-1 option card is done
correctly and the proper function by testing the port.
This test includes a BER test for each option card tributary port, and a port alarm test.
Estimated duration
10 minutes.
Remarks
This test requires two STM-4 SFPs.
Test setup
The following figure illustrates a possible test setup:
ote:
Install in port LP1.1 and LP1.2 an STM-4 SFP. For Long Haul lasers a 10 dB
optical attenuator must be installed in both connections between LP1 and LP2.
Start condition
Ensure that the following start condition is fulfilled:
•
The procedure in section
“Preparation and test of the main unit” (p. 7-4)
must have
been performed and the test results are correct.
•
The ITM-CIT must be connected and logged-in to the E.
•
Test setup as shown in the figure above
Procedure
Proceed as follows to perform the optical STM-1 option card test:
...................................................................................................................................................................................................
1
Assign the installed option card.
Figure 7-4 Optical STM-1 option card test
Stand-alone test procedures
Optical X6STM1 option card test
...................................................................................................................................................................................................................................
...................................................................................................................................................................................................................................
365-313-103R8.0
Issue 2
July 2009
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
7-15