1645 AMC with an option card
Option cards
Accessories
E1
E3
DS1
DS3
STM-1
Optical
Trans
LAN
X8PL
Trans
LAN
X5IP
X12
SHDSL
2x E1 cables
X
PDH BER test set with
E3 option
X
2x E3 cables
X
PDH BER test set with
DS1 option
X
2x DS1 cables,
refer to note 1
X
PDH BER test set with
DS3 option
X
2x DS3 cable,
refer to note 1
X
2x optical fibers,
single/multi mode
depending on the used
SFP
X
X
1x Ethernet CAT 5
crossed UTP cable
X
X
1x SHDSL cable
(see chapter 4, section
“SHDSL interfaces
(X12SHDSL-V2
card)” (p. 4-25)
X
SHDSL E1 modem
X
Note
Since the pulse shape for DS1 and DS3 signals is defined at the DDF, the cable length
between the port and the DDF must be compensated for each port output (Menu:
Port
Provisioning
,
Cable length
). By default the cable compensation is set to 0-131 feet (DS1)
or 0-120 feet (DS3). Because the PDH analyzer is connected close to the DDF, the
receiver will deal with the cable loss. However for each port the length between port and
DDF should be estimated and compensated by selecting the proper length range before
the other side is connected.
Stand-alone test procedures
Test equipment and accessories
...................................................................................................................................................................................................................................
...................................................................................................................................................................................................................................
365-313-103R8.0
Issue 2
July 2009
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
7-3