12
Instructions for re-activating the PE1 (FRONT)
1.
Press and hold the
Reset/Menu
button
for 3-5 seconds.
2.
The display will read
LIMIT SETUP
. Press the
UP ARROW
button until the
display reads
MODULE CONFIGURATION
. Press the
ENTER
button.
3.
Press the
UP ARROW
button until the display reads
MOD B…
Press the
ENTER
button two times.
4.
The display will read
Not Assigned
. Press the
ENTER
button.
5.
Press the
UP arrow
button until
Photo 1(front)
is displayed. Press
enter
.
6.
The cursor will be flashing under the
NO
in lower left hand corner, press the
UP
ARROW
button and change to.
NC.
Press
Enter
.
7.
Press the
RESET
button two times to get back to the main menu. Push the
RESET
button again to get the door ready to run. The display will read
DOOR READY
and the cycle count.