11
Instructions
for
De
‐
Activating
the
PE
1
input
(Front
Photo
eye)
1
.
Press
and
hold
the
RESET/MENU
Button
for
3
–
5
seconds.
2
.
The
display
will
read
LIMIT
SETUP
.
Press
the
UP
ARROW
button
until
the
display
reads
MODULE
CONFIFURATION
.
Press
the
ENTER
button.
Press
the
UP
ARROW
button
until
the
display
reads
MOD
B…
press
the
ENTER
button
two
times.
3
.
The
display
will
read
PHOTO
1
(Front
).
4
.
Press
the
ENTER
button
until
the
cursor
is
flashing
underneath
the
word
PHOTO
1
(FRONT
).
Press
the
UP
ARROW
button
until
the
display
reads
NOT
ASSIGNED
.
5
.
Press
the
ENTER
button
6
.
The
cursor
will
be
blinking
in
the
lower
left
hand
corner.
‐
If
the
display
reads
NC
at
the
cursor,
press
the
UP
ARROW
button
to
change
this
to
NO
.
‐
If
the
display
reads
NO
at
the
cursor,
go
to
the
next
step
7
.
Press
the
ENTER
button.
The
cursor
will
go
away
and
the
display
will
read
NOT
ASSIGNED
and
NO
in
lower
left
corner.
8
.
Press
the
RESET
button
two
times
to
get
back
to
the
main
menu.
Push
the
RESET
button
again
to
get
the
door
ready
to
run.
The
display
will
read
DOOR
READY
.
9
.
The
door
is
now
ready
to
RUN.
Summary of Contents for R-BAC UltraSmart
Page 1: ...UltraSmart ...
Page 18: ...18 ...