3 Troubleshooting Functional Failures During Operation
49
3.6 IPv4 network communication failures
3.6.1 Communication is not possible or is disconnected
There are three probable causes of problems that occur during communication on an IPv4
network employing a Switch:
1.
A configuration related to IP communication is changed.
2.
The network configuration is changed.
3.
A network device fails.
For causes 1 and 2, check the differences in the configuration and network configuration
before and after the change to uncover any cause that could disable communication.
This subsection describes the procedure for isolating the fault location to determine the
cause of a problem, and applies mainly to cause 3 failures. For example, IP communication
might not be possible even when the configuration and the network configuration are
correct, or for operation that hitherto has been normal, IP communication is no longer
possible.
Use the following flowchart to isolate the fault location to identify the cause of the problem.
Figure 3-5
Failure analysis procedure when IPv4 communication is not possible