3 Troubleshooting Functional Failures During Operation
87
No.
Items to check and commands
Action
4
When the user logs in to the console
(RS-232C), the LEDs do not light
with the normal brightness
(automatic operation is disabled).
Use the
show
system
operation command to check the
information displayed for
Brightness
mode
.
normal
displayed:
LED operation is set to normal brightness. Check the setting
of the
system
port-led
trigger
configuration
command.
If
console
is not set in the
system
port-led
trigger
command, the console is not specified as the trigger for
automatic operation. Specify the console as the trigger for
automatic operation.
Other than above:
Check the configuration.
3.17.2 Power saving scheduling is disabled
If a problem occurs in scheduling power saving, perform the check procedure described in
the following table.
Table 3-34
Problems in power saving scheduling, and action to take
No.
Items to check and commands
Action
1
The Switch does not enter sleep
mode at the scheduled time.
Check whether a user who has logged in (via serial cable or
Telnet) to the Switch used configuration command mode.
If there was such a user, save the settings and exit configuration
command mode.
Check whether
action
disable
is set for the scheduled time
range (
schedule-power-control
time-range
).
If it is set, change the setting to
action
enable
and save the
setting.
2
After the sleep period ends, the
Switch does not run with the
specified configuration.
When the Switch enters sleep mode on a schedule, any
configuration that has not been saved to that point is discarded.
Set the configuration again and save it by using the
save
command.
3
Sleep mode needs to be temporarily
canceled.
Hold down the
RESET
button on the Switch for at least three
seconds until all LEDs on the front of the Switch turn on.
Note that the schedule-disabled mode is set after the sleep mode
is canceled. The Switch will automatically enter schedule-enabled
mode when the scheduled time range expires and a normal time
range begins.
4
After the forced cancellation of sleep
mode, the Switch enters sleep
mode again after startup.
When the wake-up option (
schedule-power-control
wakeup-option
) is set, briefly pressing the
RESET
button for
less than three seconds does not trigger the forced cancellation of
sleep mode.
To forcibly cancel sleep mode, hold down the
RESET
button until
all LEDs on the front panel of the Switch turn on.
5
When the wake-up option is set,
sending WOL packets to the port
configured to detect the reception of
WOL packets fails to cancel sleep
mode.
1.
Make sure that the wake-up option is configured.
2.
Specify the MAC address of the Switch as the MAC address
of WOL packets. If you specify the MAC address of the port,
the WOL packets will not be recognized as the packets for
which the wake-up option is configured.
Summary of Contents for AX2500S
Page 1: ...AX2500S Troubleshooting Guide AX25S T001X 60...
Page 6: ......
Page 34: ...1 Overview 8...
Page 40: ...2 Troubleshooting Switch Failures 14...
Page 106: ...3 Troubleshooting Functional Failures During Operation 80 config...
Page 116: ...3 Troubleshooting Functional Failures During Operation 90...
Page 121: ...95 5 Line Testing 5 1 Testing a line...
Page 126: ...5 Line Testing 100...
Page 127: ...101 Appendix A Detailed Display Contents of the show tech support Command...