Section 3
System Overview
3.1 Electrical Ratings and Specifications
Manufactured By
www.alarmsaf.com
Fax: 978 658 8638
Wilmington, MA 01887
Tel: 978 658 6717
65A Industrial Way
Tel: 800 987 1050
AlarmSaf
Model Numbers (Board-Level)
APD8, APD8F
Electrical Ratings
0.01A @ 24VDC
FAI Trip Current
0.03A per input
Input Trip Current
Dependant on input voltage
Zone Output Voltage
APD8 - 1.6A maximum ; APD8F - 3.0A maximum
Zone Output Current
8A maximum output current or rating of power source - whichever is less
Total Output Current
0.4A@12VDC/0.2A@24VDC maximum control c 8A maximum output current
Input Power
10 - 30V AC or DC
Input Voltage
Product Use
When installed in accordance with all standards listed in Section 2 of this document, the APD8(F)
provides power distribution for use with typical 12 or 24VDC devices used in the access control or
security industries such as, but not limited to, mag locks, door strikes, door holders, card readers,
keypads, etc.
APD8(F) Installation Instructions
10/9/2007, 12:19:29 PM
Page 6 of 24
AlarmSaf
65A Industrial Way, Wilmington, MA 01887 978 658 6717 www.alarmsaf.com
52-254 Rev B01