background image

Table of Contents 

Lock Features .............................................................3  

Supported Products ..................................................4  

Lock Design Overview ..............................................5  

Terminology Used in this Manual ............................6  

Programming Levels .................................................8  

Conventions Used in this Manual ............................9  

LED and Sounder Indicators ....................................9 

Wiring and Power Up .............................................. 10 

Quick Start ................................................................ 11 

Testing the Codes Entered ....................................13 

Programming Functions Overview .......................14 

Programming Functions ...................................15-27 

Groups and Scheduled Group 1 Examples ....28-29 

Programming Record Sheet ..................................30 

User Code Record Sheet ........................................31 

Schedule Record Sheet ..........................................33 

Glossary ...............................................................35-36 

Warranty ....................................................................36 

T

HE

 

A

LARM

 L

OCK

 

T

RILOGY

 S

ERIES

 S

TAND

-A

LONE

 

AND

 N

ETWORK

 P

ROGRAMMABLE

 A

CCESS

 C

ONTROL

 S

YSTEM

 

IS

 

A

 

SERIES

 

OF

 S

TATE

-

OF

-

THE

-A

RT

 W

IRELESS

 

AND

 K

EYPAD

-E

NTRY

 P

ROGRAMMABLE

 S

ECURITY

 L

OCKS

DL6100 

The DL6100 is designed to allow all features to be programmed either at the key-
pad or through its radio link to a DL-Windows equipped computer.  In addition, Au-
dit Log Data may be transmitted through the radio link back to the DL-Windows 
computer. 
 

The DL Series features a real-time clock/calendar that automatically adjusts for 
Daylight Saving Time and allows for automated programming of events.  Up to 
5000 unique user codes can be added to the lock, from 3-6 digits in length. 
 

Wireless Network and DL-Windows 

If your Networx wireless network is not yet set up, you can add Users and pro-
gram other features using the DL6100 keypad as a 

temporary 

convenience to al-

low the lock to be put into use before installing the wireless network.  Be aware 
that all programming added using the keypad 

cannot 

be retrieved into DL-

Windows, so if you decide to start programming using the lock keypad, we recom-
mend you keep hardcopy records (in a secure location) of all Users and User 
Codes that may have been programmed.  Keeping these hardcopy records will 
save time because after the wireless network is set up, all programming added via 
the lock keypad can easily be re-added to DL-Windows and downloaded back to 
the lock(s).   

 
These instructions include manual keypad programming for the DL6100.   
For DL-Windows user instructions, see OI237.  

DL6100 LOCK 

Trilogy

®

 is a registered trademark of Alarm Lock.  Microsoft

®

 and Windows

®

 are 

trademarks of their the Microsoft Corporation. 

DL6100 

Summary of Contents for DL6100

Page 1: ...45 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 Publicly traded on NASDAQ Symbol NSSC ALARM LOCK 2011 DL WINDOWS PROGRAMMING SOFTWARE AL IM SERIES GATEWAY MODULE AL IM80211 AL IME AL IMEPOE DL6100 ...

Page 2: ...that automatically adjusts for Daylight Saving Time and allows for automated programming of events Up to 5000 unique user codes can be added to the lock from 3 6 digits in length Wireless Network and DL Windows If your Networx wireless network is not yet set up you can add Users and pro gram other features using the DL6100 keypad as a temporary convenience to al low the lock to be put into use bef...

Page 3: ...r Quick Schedules contains 4 most common schedules see page 25 Real time clock and calendar see page 19 Programmable Timeout Functions see page 16 20 User Access Methods Keypad Entered User Codes see pages 11 12 15 User Features 5000 Users see pages 11 12 15 5 Pre defined Administration User Levels including Master Installer Manager Supervisor and Basic User Codes see page 8 User Code Lengths from...

Page 4: ...nection to the DL6100 and the other for 802 11 network transmissions Ensure adequate 802 11 coverage in the area where the Wireless Wired Gateway is mounted Supports up to 63 Networx Locks Ceiling or wall mountable Wired AL IME Hardwired Gateway Interface Module supports up to 63 Networx Locks connects directly to a network using a standard RJ 45 Ethernet cable This model has one antenna used to t...

Page 5: ...Program Mode When you want to make changes to the lock program you enter Program Mode When you finish programming and wish to put the lock into use you exit Program Mode to enter Normal Mode You can enter Program Mode using the keypad by pressing the Master Code of the lock that was set at the factory then wait for the green light and press until multiple beeps are heard The Master Code is basical...

Page 6: ...fines the range of programming tasks a User is allowed to perform The higher the Level the more pro gramming tasks the User is allowed with Master allowing ALL tasks Note Since the Programming Level is closely associated with the type of User and their abilities a User who holds a certain Programming Level is sometimes referred to by their User Type For example DL6100 Series locks can hold up to 5...

Page 7: ... Down to lock all doors in the Account press 000 to issue Global Passage to unlock all doors in the Account press 123 to return all locks in the Account to normal non emergency operation Note 3 chirps sound after each emergency command entry See the DL Windows user guide OI352 Emergency Lock Down for more information Note DL Windows does not need to be running to allow these Emergency commands to ...

Page 8: ...ram ming Level as follows Master Always associated with User number 1 Is always enabled and can program all functions Abbreviated as Programming Level M Installer Always associated with Users 2 and 3 Can pro gram all functions except changing the Master Code Abbreviated as Programming Level 4 Manager Always associated with Users 4 5 and 6 Can program all functions except functions relating to lock...

Page 9: ...eviated as follows M Master 4 Installer 3 Manager 2 Supervisor This Program Level abbreviation is the minimum program level required to access the particular Function The higher the level the more programming tasks the User is allowed with Master allowing all tasks Function Description Function Number Function Name ACTIVITY LED SOUNDER COMMENTS Keypress 1 RED Flash 1 Beep Normal Operation Access G...

Page 10: ... 3 Re install the battery pack lock will sound 3 short beeps If beeps are not heard then restart at step 1 4 Within 5 seconds after hearing the 3 short beeps press and hold until the lock begins to beep then release 5 A series of 5 RED LED and 5 beeps will be heard followed by 10 seconds of silence then 3 GREEN LEDs and 3 fast beeps All settings and programming have been erased and the lock is now...

Page 11: ...the second set of digits must be exactly the same For example if you want your new Master Code to be 664433 Press 1 664433 664433 Now that the Master Code has been changed there is no need to change it again unless you want to Since you are still in Program Mode you can now proceed directly below and program various functions Note Programming any Function such as setting the clock follows a consis...

Page 12: ...a new User Code that matches the first digits of the Master Code WARNING When attempting to change an existing Master Code it is HIGHLY recommended that you enable all Groups see Function 23 on page 17 exit Program Mode and enter the new anticipated Master Code to verify that the anticipated sequence does not currently open the lock If the lock does not open the anticipated Master Code can be used...

Page 13: ...____________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________...

Page 14: ...ge 20 Function 47 Timed Passage Mode See page 20 Programming Functions Overview Function 48 Enable Passage Mode See page 21 Function 49 Disable Passage Mode See page 21 Function 50 Return Lock to Normal Passage Mode Schedule See page 21 Function 51 Passage Mode Configuration See page 21 Function 52 54 Pass Time See page 21 Function 55 Reserved Function 56 Reserved Function 57 Reserved Function 58 ...

Page 15: ...one This code is a Non Pass code and therefore does not allow passage through the door 1 New Master Code User Number 1 1 _ _ _ _ _ _ _ _ _ _ _ _ New Master Code Confirm New Master Code 2 Adding and Deleting User Codes for User Numbers 2 5000 2 _ _ _ _ _ _ _ _ _ _ User Number User Code Master Code must be 6 digits only Master Code is Keypad Code Access only Factory Default 123456 See Lock Design Ov...

Page 16: ...ork day by entering Program Mode and pressing 5 1157 008 NOTE Up to 4 Timeout Functions may be pending at any one time An error beep will sound when attempting to program more than 4 Timeout Functions 2 Service Code is a One Time Only Code Once it is used it is disabled until enabled again NOTE User Number 297 is used to reset Service Code Use See Terminology Used in this Manual on page 7 for more...

Page 17: ...emain 3 13 Clear All Timeout Functions This Function enabled through keypad only CLEAR FUNCTIONS Group Enable Disable Enter the functions below to Enable Disable Groups Functions 14 23 will each override existing scheduled events Therefore Functions 14 23 are temporary take effect im mediately and are always overridden by future scheduled events that already exist within the lock programming 2 GRO...

Page 18: ... Association As per the chart on page 8 the lock s default programming from the factory associates certain User Numbers with certain Groups To override these default Group associations Function 35 manually associates or disassociates a selected User with a selected Group During programming Groups not selected are then disassociated from the User Function 35 is helpful when the number of Users you ...

Page 19: ...nd ends at 2AM on the programmed date Enter 4 1 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Default DST Start Date March Week 2 Sunday Second Sunday in March Default DST End Date November Week 1 Sunday First Sunday in November To program the DST start date using the keypad press 4 1 M M W D whe...

Page 20: ...s Note Repeated use of these Functions are not cumulative this means for exam ple if the clock has already been set to speed up 10 seconds per day and then is found to need an additional 10 seconds then program 20 seconds using Function 43 Example 1 Clock is losing 13 seconds every day enter 4 3 1 3 This example assumes that the Clock Adjust setting was at the factory default of zero Example 2 Clo...

Page 21: ...Code is entered When the Pass Time expires the lock will re lock automatically Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Pass Time 4 53 Set Pass Time to 10 Sec 54 Set Pass Time to 15 Sec PASS TIME See Scheduled functions 72 and 73 for Scheduled Passage Mode NOTE 51 Passage Mode Configuration 5 1 _ Mode Mode 1 Normal Passage Mode m...

Page 22: ...UT 6 4 64 Disable Remote Input Wire a Normally Open Contact to Wires White White Momentarily close switch to unlock door to allow person to pass through door Enter the functions below to Disable Enable the Remote Input NOTE The Remote Input is enabled as part of the default program Remote Input 6 5 65 Enable Remote Input 6 6 _ _ Ambush Code 66 Ambush Code Ambush code must be 2 digits An error will...

Page 23: ...stem Options 24 One Time Access for Group 3 Users 25 Disable Sounder 26 5 sec Delayed Entry 27 15 sec Delayed Entry 28 45 sec Delayed Entry Remote Input Functions 29 Toggle Passage Mode Remote Input toggles Passage Mode 30 Forced Unlock Follows Remote Input When Remote Input switch is closed regardless of the current state of the lock the lock unlocks for the duration of the Remote Input switch cl...

Page 24: ...2 8 0 _ _ _ _ _ Day Time 81 Schedule Disable Group 3 8 1 _ _ _ _ _ Day Time 82 Schedule Disable Group 4 8 2 _ _ _ _ _ Day Time 83 Schedule Disable All Groups 8 3 _ _ _ _ _ Day Time 3 Clear All Schedule and Timeout Functions by entering Function 12 To set the time see Function 39 NOTE 72 Schedule Enable Passage Mode Unlock 7 2 _ _ _ _ _ Day Time 73 Schedule Disable Passage Mode Lock 7 3 _ _ _ _ _ D...

Page 25: ...7 for Saturday 8 for Monday to Friday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Scheduled Passage Mode Group 1 Activated 89 Passage Mode Close Time Window This Function enabled through keypad only 8 9 _ _ _ _ _ Day Time SCHEDULES GROUP 1 ACTIVATED 3 For your convenience your lock comes pre programmed with Quick Sche...

Page 26: ...ime of day in 24 hour format for example for 2 15 PM enter 14 15 Scheduled Relay Activation Group 1 Activated 9 1 _ _ _ _ _ Day Time 91 Relay Activation Close Time Window SCHEDULES GROUP 1 ACTIVATED 3 NOTES 1 Group 1 Disarms a Burglary Control Panel will always disarm an alarm system Arming should be performed by other means such as Alarm Panel Keypad Schedule 2 Use a qualified electrical alarm sp...

Page 27: ...or Monday to Friday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 3 Programming Functions cont d 93 Enable Group 4 Close Time Window This Function enabled through keypad only 9 3 _ _ _ _ _ Day Time Scheduled Group 4 Enable Group 1 Activated Disable Radio Signal 94 Disable Radio This Function enabled through keypad only ...

Page 28: ...ption See To Disarm a Burglary Control Panel on page 26 If a Group 1 User does not enter their User Code during the specified window Func tions 90 91 remain inactive Function 92 and 93 allow for a window of time to be created where if any Group 1 User Code is entered within the programmed window the User Codes in Group 4 will be enabled If a Group 1 User does not enter their User Code during the s...

Page 29: ...nction of the alarm panel Functions 92 93 Use Function 92 and 93 see page 27 to create a window of time where if any Group 1 User Code is entered within the programmed window Group 4 Users will be enabled 1 Enter Program Mode if not in already 2 Using Function 2 create User 4 with a User Code of 456789 Press 2 4 4 5 6 7 8 9 3 Because User 4 does not have a default Group association make User 4 a m...

Page 30: ...e Input enabled 2 Remote Input switch closed and Function 64 Remote Input disabled 3 Failed attempted entry 4 Disabled User or Group 5 Follow Access Granted 6 Group 1 User Code 7 Scheduled Lock Event 8 Scheduled Unlock Event 9 Lock Out 10 Ambush 11 First Key Press 25 Disable Sounder 26 5 sec Delayed Entry 27 15 sec Delayed Entry 28 45 sec Delayed Entry 29 Toggle Passage Mode 30 Forced Unlock Follo...

Page 31: ...31 User Number 1 5000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from the DL WINDOWS software Note ...

Page 32: ...32 User Number 1 5000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from the DL WINDOWS software Note ...

Page 33: ...unctions can be programmed For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter time of day in 24 hour format 00 00 23 59 Time Function Name ...

Page 34: ...unctions can be programmed For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter time of day in 24 hour format 00 00 23 59 Time Function Name ...

Page 35: ... are permanently encoded within the lock s fixed memory and when the lock is first started or when power is removed and re applied see Wiring and Power Up page 10 the original factory default settings are re loaded and take effect DISABLE Turn off DOWNLOAD Send data to the lock EMERGENCY COMMANDS For use with the Trilogy Net worx wireless network only Wireless commands can be sent to all wireless ...

Page 36: ... assumes the cost of returning products under warranty ALARM LOCK shall have no obligation under this warranty or otherwise if the product has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire or acts of God or on which any serial numbers have been altered defaced or removed ALARM LOCK will not be responsible for any disma...

Reviews: