9
Programming Key Sequence
.
Programming
Information
General Program Mode Information
If a wrong key is pressed during code entry, press the
;
key until the error sound is heard (7 short beeps), this will clear the entry. Re-enter the
key sequence again.
All program sequences are followed by the
:
key; 2 short beeps indicate a successful program sequence.
Enabling/Disabling Users (By User Number)
3. Disable User
;
3
;
[ _ _ _ ]
:
4. Enable User
;
4
;
[ _ _ _ ]
:
User Number must be between 2 and 5000.
NOTE: Will Enable/Disable users even if the user is associated with an enabled group.
2
Conventions Used in this Manual
LED and Sounder Indicators
The DL6100 Series locks provide visual and audible keypad feedback. With a fully charged battery, the LED and sounder
feedback is as follows:
Minimum Required Program Level
Program Levels are abbreviated as follows:
M
= Master
4
= Installer
3
= Manager
2
= Supervisor
This Program Level abbreviation is the
minimum
program level required to
access the particular Function. (The
higher the level, the more programming
tasks the User is allowed, with
Master
allowing all tasks).
Function
Description
Function
Number
Function Name
ACTIVITY
LED
SOUNDER
COMMENTS
Keypress
1 RED Flash
1 Beep
Normal Operation
Access Granted or Remote Release
2 GREEN Flashes
2 Beeps
Remote release enabled through
activation of relay
Invalid Code
7 RED Flashes
7 Beeps
Re-enter User Code
Successful Program Entry
2 GREEN Flashes
2 Beeps
When in Program Mode
Unsuccessful Program Entry
7 RED Flashes
7 Beeps
When in Program Mode
Exit Program Mode
1 RED, 2 GREEN Flashes
10 Beeps
Valid but Disabled Code
1 GREEN, 4 RED Flashes
1 long, 5 short beeps
Code exists in memory, but disabled
Low Battery
RED Flashes for
Four Seconds
4-Second Pulsing Beep
See page 10 before changing batteries
Emergency Commands are in effect
1 RED Flash every
two seconds
--
--