AL-KO AIRSAFE 1200 Operating Manual Download Page 41

Subject to changes in line with technical progress!

41

3426558

EC Declaration of Conformity in accordance with 2006/42/EC

11 

EC Declaration of Conformity in accordance with 2006/42/EC

The following EU Declaration of Conformity is issued individually for each order, depending on its validity.

Both the order number and the position of the device is indicated. The issued document is therefore specific to the 

respective device.

 

 

EG-KONFORMITÄTSERKLÄRUNG

EC DECLARATION OF CONFORMITY

DÉCLARATION DE CONFORMITÉ CE

 

 

Hersteller

/

Manufacturer / Fabricant:

AL-KO THERM GMBH I Hauptstraße 248-250 I 89343 Jettingen-Scheppach I Germany

 

Im Sinne der EG- Maschinenrichtlinie 2006/42/EG, Anhang II, Teil 1, Abschnitt A

As defined in EC Machinery Directive 2006/42/EC, Annex II, Part 1, Section A

Au sens de la directive Machines CE 2006/42/CE, annexe II, partie 1, section A

 

 

Produkt

/ Product / produit:                                            

Luftreiniger

/ Air cleaner / purificateur d

’a

ir

Typ 

/ type / Type:

AL-KO

AIR

SAFE

1200, 

AL-KO

AIR

SAFE

1600

Hiermit erklären wir, dass die oben genannte Maschine alle sicherheitstechnischen Anforderungen der folgenden anwendbaren EG/EU- Richtlinien 

erfüllt:

We hereby declare that the above-mentioned machine conforms to all relevant safety-provisions of the following EG/EC directives:

Nous déclarons par la présente que la machine 

susmentionnée corresponde à toutes les des exigences de sécurité pertinentes de la directive CE/UE

suivante:

Maschinenrichtlinie 2006/42/EG

/

Machinery Directive 2006/42/EC / Directive Machines CE 2006/42/CE:

Niederspannungsrichtlinie 2014/35/EU 

/ Low Voltage Directive 2014/35/EU / Directive Basse Tension 2014/35/UE

Angewandte harmonisierte Normen

/

Applied harmonized standards / Normes harmonisées appliquées :

- DIN EN ISO 12100-1/-2,

Sicherheit von Maschinen 

Allgemeine Gestaltungsleitsätze 

Risikobeurteilung und Risikominderung

Safety of machinery - General principles for design - Risk assessment and risk reduction

Sécurité des machines 

Principes généraux de conception 

Appréciation et réduction du risque

- DIN EN 60204-1,

Sicherheit von Maschinen 

Elektrische Ausrüstung von Maschinen 

Teil 1: Allgemeine Anforderungen

Safety of machinery - Electrical equipment of machines - Part 1: General requirements

Sécurité des machines 

Equipement électrique des machines 

Partie 1 : exigences générales

- DIN EN 349, 

Sicherheit von Maschinen - Mindestabstände  zur Vermeidung des  Quetschens von Körperteilen

Safety of machinery - Minimum gaps to avoid crushing of parts of the human body

Sécurité des machines 

Distances minimales de prévention des contusions de parties du corps humain

- DIN EN ISO 13857,

Sicherheit von Maschinen 

Sicherheitsabstände gegen das Erreichen von Gefährdungsbereichen mit den oberen und unteren Gliedmaßen

Safety of machinery - Safety distances to prevent hazard zones being reached by upper and lower limbs

Sécurité des machines 

– Distances de sécurité empêchant l’entrée dans les zones dangereuses des membres supérieurs et inférieurs

- DIN EN 60335-1:2020-08

Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke 

Teil 1

Household and similar electrical appliances 

Safety 

Part 1

Sécurité des équipements électriques ménagers et similaires 

Partie 1

- DIN EN 60335-2:2013-02

Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke 

Teil 2-65

Household and similar electrical appliances 

Safety 

Part 2-65

Sécurité des équipements électriques ménagers et similaires 

Partie 2-65

Bei einer mit uns nicht abgestimmten Änderung der Maschine verliert diese Erklärung ihre Gültigkeit.

Any modification of this machine without confirmation shall automatically annul this declaration.

En cas de modification de la machine non convenue avec nous, la présente déclaration perd sa validité.

 

Bevollmächtigter für die Zusammenstellung der technischen Unterlagen

:

Leiter der Abteilung Entwicklung

Authorized representative in charge of the technical document compilation

:

Head of Development Department

Personne autorisée à constituer le dossier technique

Chef du département de développement

Anschrift siehe Hersteller

/

see manufacturer's address above / Adresse, voir fabricant

 
 
 

Jettingen-Scheppach, 11.12.2020

 

Dr. Christian Stehle

Geschäftsführer /

Managing Director / Directeur général

 

Summary of Contents for AIRSAFE 1200

Page 1: ...AIR PURIFIER EN OPERATING MANUAL AL KO AIRSAFE 1200 1600...

Page 2: ...2 AL KO AIRSAFE 1200 1600 Legal AL KO THERM GMBH Hauptstra e 248 250 D 89343 Jettingen Scheppach Germany Fon 49 8225 39 0 Fax 49 8225 39 2113 E mail klima technik al ko com Revision history Version De...

Page 3: ...l data 16 3 2 1 General technical data 16 3 2 2 Air filtration data 16 3 3 Rating plate of the AL KO AIRSAFE 1200 1600 air purifier 17 4 Delivery transport storage 18 4 1 Delivery 18 4 1 1 Scope of su...

Page 4: ...change indicator 32 7 3 3 Preparation 32 7 3 4 Replace pre filter 33 7 3 5 Replace HEPA filter 34 7 3 6 Complete the filter change 35 7 4 Circuit diagrams 36 8 Help in the event of faults 37 8 1 Safe...

Page 5: ...k and trouble free handling Observe the safety instructions and warnings in this documentation and on the product This documentation is a permanent part of the described product and must be handed ove...

Page 6: ...ty instructions are not observed this can lead to severe injury or even death due to hazardous electric shock Warning of crushing hazard If the necessary safety instructions are not observed this can...

Page 7: ...ed to the feet Wear hand protection If hand protection is not worn injuries may be caused to the hands Wear breathing masks If respiratory protection is not worn poisoning and chemical burns to the lu...

Page 8: ...ting repair or maintenance work Avoid naked flames and sparks in the intake area of the device Observe the working instructions and these installation instructions and the operating manual Work carefu...

Page 9: ...full before starting work on the device and must observe them at all times In order avoid hazards during operation all company operating and work instructions of the user apply in addition to these i...

Page 10: ...rs The device may pose hazards if it is not operated by trained personnel and or is operated improperly or not according to its intended use Residual dangers are potential hazards that are not immedia...

Page 11: ...ning agents used 2 2 2 Training The owner operator of the AL KO AIRSAFE 1200 1600 air purifier must brief his personnel on the following subjects at regular intervals Compliance with the installation...

Page 12: ...FE 1200 1600 air purifier may only be operated within the limits of the technical data specified by AL KO THERM Any other use or use beyond that described in section 2 2 3 Intended use on page 11 is r...

Page 13: ...air purifier on page 17 The device is suitable for operation in the temperature range from 20 C to 40 C The device consists of one component The device is available only for indoor installation 3 1 F...

Page 14: ...ures extremely quiet continuous operation of the air purifier In order to guarantee a high quality of the cleaned air leaving the outlet hood 17 the filter is constantly monitored by means of a differ...

Page 15: ...1 3 2 Hygiene timer NOTE The illustration of the hygiene timer is purely an example The hygiene timer on your device may differ slightly from that illustrated here 1 2 3 4 5 1 Scale fill level indicat...

Page 16: ...E 1200 AL KO AIRSAFE 1600 Dimensions W x D x H in mm 661 x 418 x 1900 661 x 573 x 1900 Weight in kg 100 128 Intended room sizes 20 m2 to 140 m2 30 m2 to 180 m2 Article No 340 6881 340 6882 3 2 2 Air f...

Page 17: ...ct description 3 3 Rating plate of the AL KO AIRSAFE 1200 1600 air purifier The article number serial number year of construction manufacturer information and the design data can be found on the ratin...

Page 18: ...O AIRSAFE 1200 1600 air purifier is delivered wrapped in plastic foil and mounted on a one way pallet The intake grille is packed separately in plastic foil The AL KO AIRSAFE 1200 1600 air purifier ma...

Page 19: ...tandards directives and regulations leads to a risk of injury due to the device falling or tipping over Observe the applicable standards directives and regulations Observe the instructions in these in...

Page 20: ...under aggravated conditions When transporting under aggravated conditions e g on open vehicles under unusual vibrational stresses trans port by sea or in subtropical countries additional packaging mus...

Page 21: ...ce to its setup location NOTE To protect the surface of the device during transport we recommend that the outer packaging plastic foil is left on the device and removed only at the final setup locatio...

Page 22: ...contact your Customer Service Pay attention to unusual noises when switching on the device after prolonged storage If in doubt switch off the device immediately at the device main switch Disconnect th...

Page 23: ...rried out by a qualified electrician Visually inspect the mains lead and mains plug for damage Ensure that the mains lead is routed correctly Ensure that the device is not standing on the mains lead W...

Page 24: ...ith the control panel are closed and screwed tight 3 Ensure that the air purifier is standing on a level surface with sufficient load bearing capacity 4 Ensure that the domestic power socket is within...

Page 25: ...nsure that no access or escape routes are obstructed when routing the mains lead The AL KO AIRSAFE 1200 1600 air purifier has a five metre long mains lead with 230 V mains plug normal domestic power s...

Page 26: ...ructions and the operating manual see 5 In stallation on page 23 All the filter elements are correctly installed The device is connected to the mains power supply WARNING Risk of damage to property Th...

Page 27: ...to position I The fan goes into operation Pay attention to the green Run LED 5 on the control panel 3 it must come on The device is ready for operation 3 Set the air flow rate to the air filtration r...

Page 28: ...power supply to the air purifier can be switched on and off with a timer at the mains plug This can be expedient for room that are heavily frequented at certain times e g In classrooms in schools The...

Page 29: ...ty rules Have installation commissioning maintenance and repair work carried out only by qual ified specialist personnel Make sure that all safety devices installed at the factory are functional befor...

Page 30: ...The owner operator of the air purifier is obliged to have the device serviced at regular intervals by qualified personnel AL KO recommends that maintenance is carried out in accordance with the Germa...

Page 31: ...ins lead so that it does not pose a tripping hazard Never open the rear housing cover of the device WARNING Health hazards due to dust load and microbial contamination Lack of maintenance of the filte...

Page 32: ...ated Switch on the device again Lights up even though the pre filter has been replaced Replace HEPA filter Switch on the device again Not lit Device is in operation The pre filter must also be changed...

Page 33: ...rom the fixation 1 2 Swivel the filter clamps 90 away from the holder 4 3 Pull the frame 5 with the pre filter 3 out of the holder 4 Place the frame with the new pre filter into the holder 5 Swivel th...

Page 34: ...guide rail 4 Housing Proceed as follows to replace the HEPA filter Step Action 1 Pull the HEPA filter 1 completely out of the housing 4 of the air purifier 2 Place the new HEPA filter into the guide...

Page 35: ...ith the rear side to the wall Use the handle recess on the rear side of the device for positioning 6 Check that the air purifier is set up on level ground Correct the alignment of the device if necess...

Page 36: ...Gr n Gelb 3 2 1 3 2 1 4 3x0 75 4x0 75 1 9 3 4 5 6 7 8 2 Druckdose Einstellwert 30Pa 1 2 3 1 2 6 3A 0 I 10 kOhm 10V 10V Filter status Run 5 1 kOhm L N PE 1 2 3 1 2 3 5 6 7 8 10 11 12 13 Druckdose Einst...

Page 37: ...the mains fuse Disconnect the mains plug and inspect for damage Red Filter status LED on the control panel lights up Pre filter soiled Replace pre filter see 7 3 4 Replace pre filter on page 33 Red Fi...

Page 38: ...njunction with our products please contact one of our branches or contact us directly at AL KO THERM GmbH Fon 49 82 25 39 2440 Hauptstra e 248 250 Fax 49 82 25 39 2113 D 89343 Jettingen Scheppach E ma...

Page 39: ...hygiene timer 3407764 Control panel 3406732 Filter clamps 4x 3407152 Mains cable 3406840 Fan 3406721 Plug for non heating appliances 3406839 Load cell 964291 9 2 Proof of delivery AL KO THERM GmbH Fon...

Page 40: ...ot dispose of worn out devices spent batteries or rechargeable batteries in domestic waste When disposing of the device operating equipment and accessories proceed according to the relevant local envi...

Page 41: ...risque DIN EN 60204 1 Sicherheit von Maschinen Elektrische Ausr stung von Maschinen Teil 1 Allgemeine Anforderungen Safety of machinery Electrical equipment of machines Part 1 General requirements S...

Page 42: ...Translation of the original operating manual 42 AL KO AIRSAFE 1200 1600 Notes...

Page 43: ...Subject to changes in line with technical progress 43 3426558 EC Declaration of Conformity in accordance with 2006 42 EC...

Page 44: ...THERM GMBH l Jettingen Scheppach l Germany All rights reserved for AL KO THERM GMBH as well as in the event of applications for industrial property rights This documentation or excerpts thereof may no...

Reviews: