© 2019 AKW
13-012-085-17
4
User
Safety Information
This appliance can be used by any persons (including children from
8 years and above) with reduced physical, sensory, mental or intuitive
capabilities or by any persons with a lack of experience and knowledge
of showering, only if they are supervised or have had the correct
instructions on how to operate the appliance correctly.
Children should be supervised to make sure that they do not play with
the appliance and use it correctly.
Ensure that the temperature is not set to maximum before showering.
Sunburn or skin conditions can increase your sensitivity to hot water.
Make sure that you set the shower to a cooler temperature.
Do not operate shower if you suspect the water in the heater tank is
frozen or the appliance has been susceptible to freezing conditions.
Do not operate the shower if the spray handset or hose is damaged,
twisted or blocked in anyway.
Do not restrict flow out of the shower by blocking or obstructing the
hose or spray handset.
Do not use other shower hoses and handsets with this shower. Using
other handsets or hoses will make this SmartCare Plus shower a
Non-Care approved shower. Only use AKW approved products.
Factory Temperature Settings
The shower is set to
43˚C
in its factory setting when packaged.
This is not Care approved at this temperature.
To comply with BEAB Care standard and to be Care approved, then the
maximum temperature DIP switch setting must be changed to 41
0
C.
The maximum water temperature can be set to either
41
0
C
,
(43
0
C
Factory set on
page 26) or 47
0
C
by changing the DIP switch settings located on the control
PCB inside the front cover. Do not attempt this yourself unless your are a
competent installer and have read all of these instructions before doing so.