Functional description of the control panel: 

 

 

 

A. 

TIMER (remaining time/start time 1-24 hrs.) 

1. Signal light when timer is activated 

B. 

Setting the operating strength 

2. Signal light for high operating strength (H) 

C. 

Setting the operating mode 

3. Signal light for medium operating strength (M) 

D. 

On / Off button 

4. Signal light for low operating strength (L) 

E. 

Without function on this model 

5. Signal light when automatic mode is activated 

F. 

SLEEP = Low-noise night operation 

6. Signal light when cooling mode is activated 

G. 

Display / display panel (temperature etc.)  

7. signal light when fan operation is activated 

H. 

UP button for increasing the room temperature 

8. Signal light for dehumidification mode 

I. 

DOWN button to lower the room temperature 

9. Signal light when the water tank is full 

 

10. signal light for active compressor operation 

 

11. no function on this model 

 

12. signal light when night mode is activated 

 
 

 

Instructions for use: 
 

1.  Commissioning 

 

1.1. 

Insert the mains plug properly into the socket. 

1.2. 

Check that the exhaust hose for the warm exhaust air is properly installed (see page 4-5 of the instructions 
for use). 

1.3. 

Make sure that the horizontally mounted outlet louvres are open towards the desired direction. 

1.4. 

Press the ON/OFF switch. The air conditioner switches on and the default setting Automatic mode with 
medium operating strength starts to work. The default target temperature is 24°C. At the same time, the 
operation/signal lights turn on. (Note: The room temperature display panel can display values from 0°C to 
50°C. ) 

 
 
 

Summary of Contents for WDH-FGA1372

Page 1: ...mproper transport can sometimes occur despite careful instructions on the carton Therefore please let it stand upright for at least 4 hours before using it for the first time so that the refrigerant i...

Page 2: ...sary physical and mental capabilities to operate this unit without problems This air conditioner is only approved for indoor use Only qualified personnel or electricians are allowed to open the unit O...

Page 3: ...sation water 5 water tank compartment 11 air filter 6 water tank compartment display window 12 air filter Accessories 13 exhaust air hose for warm air 14 adapter for connecting the warm air hose with...

Page 4: ...ing This warm exhaust air must be discharged to the outside You can either direct the warm exhaust air outside through a suitable hole 160 mm diameter in the wall similar to a kitchen extractor bonnet...

Page 5: ...e extended from 30 cm to a maximum of 150 cm But for maximum effectiveness and economy we recommend the shortest possible length Warning The length of the exhaust air hose is specially adapted to the...

Page 6: ...sing the room temperature 8 Signal light for dehumidification mode I DOWN button to lower the room temperature 9 Signal light when the water tank is full 10 signal light for active compressor operatio...

Page 7: ...verage operating strength C L Weak operating strength Note In automatic mode the operating strength is set automatically by the unit The operating strength you have just selected is indicated by a sma...

Page 8: ...or Dehumidification mode 8 Remote control All functions and settings as described in points 1 7 above can also be operated adjusted with the remote control supplied The remote control requires two AAA...

Page 9: ...d by the Water Full signal light on the control panel and by a beep To drain the condensation water tank and thereby reactivate the air conditioner please follow the steps below 1 Switch off the air c...

Page 10: ...rate the air conditioner without a filter Stow the air conditioner Empty any condensation water from the condensation tank Let the unit run in ventilation only mode for a few hours to allow it to dry...

Page 11: ...et or a piece of floor mat Furthermore a short exhaust hose for the warm air in the room is advantageous In the event of a defect do not attempt to repair the air conditioner yourself Technical data M...

Page 12: ...assembly instructions Completely or partially dismantled units Conformity The air conditioner has been tested and itself and or parts thereof have been manufactured under the following safety standar...

Reviews: