12.  Operating instructions regarding refrigerant R290 

 

 

Read these instructions carefully ! 

 

This air conditioner operates with the refrigerant R290, which is highly flammable and explosive. 
Therefore, please take special care that the copper lines are not damaged at any time! 

 

The appliance should not be placed in a room where other appliances are operated at the same time 
which have an electric heater or an open flame. 

 

Please note that the refrigerant is odourless and therefore a leak cannot be detected immediately by an 
emerging odour ! 

 

Make sure that the outlet of the exhaust air is always given and not obstructed by other objects ! 

 

Only appropriately trained specialists are permitted to carry out repairs to the cooling lines and the 
compressor! Always contact a specialist in case of a problem ! 

 

Do not use external heat sources to accelerate the defrosting process ! 

 

Condensation: 
 

Some condensation forms in the unit during the cooling process. This side effect is caused by the extraction of 
moisture from the ambient air during the cooling process. This condensation water is collected and fed into the 
integrated condensation tank. If the integrated condensation tank is full, the compressor and the motor of the air 
conditioner switch off. In addition, this condition is signalled by the "Water Full" signal light on the control panel and 
by a beep ! 
 
To drain the condensation water tank and thereby reactivate the air conditioner, please follow the steps below: 
 

1.  Switch off the air conditioner and avoid moving the unit when the 

condensation tank is full. 

2.  Position a drip tray below the drain hole (1) for the condensation water.   

3.  Unscrew the cap (3) and then remove the rubber plug (2) by pulling it 

out horizontally. Now the condensation water can drain out of the tank. 

4.  If your drip tray is full but there is still water in the condensation tank, 

simply put the rubber plug back on the drain hole and then empty the 
drip tray. 

5.  Repeat this procedure until the condensation tank is completely empty. 

6.  Now put the rubber plug back on the drain hole and finally screw the 

cap back on properly. 

7.  Finally, you can switch the mobile air conditioner on again and the 

"Water Full" signal light on the control panel should now go out. 

 
 
 
 
 
 
 
If you want to operate the air conditioner without the condensation tank, please take the following steps: 

 

1.  Unscrew the cap and then remove the rubber stopper by pulling it out horizontally. Keep both cap parts in a 

safe place for later use. 

2.  Connect the plastic hose supplied to the condensation drain hole and lead off the other end so that there is a 

slope and the condensation can drain off easily/unhindered (see fig. below).  

3.  The drain hose can be extended or also replaced. In this case, please use a suitable hose. A 3/4 inch hose is 

best suited/fitting. 

 
See the following graphs at the beginning of the next page:

 

 
 

Summary of Contents for WDH-FGA1372

Page 1: ...mproper transport can sometimes occur despite careful instructions on the carton Therefore please let it stand upright for at least 4 hours before using it for the first time so that the refrigerant i...

Page 2: ...sary physical and mental capabilities to operate this unit without problems This air conditioner is only approved for indoor use Only qualified personnel or electricians are allowed to open the unit O...

Page 3: ...sation water 5 water tank compartment 11 air filter 6 water tank compartment display window 12 air filter Accessories 13 exhaust air hose for warm air 14 adapter for connecting the warm air hose with...

Page 4: ...ing This warm exhaust air must be discharged to the outside You can either direct the warm exhaust air outside through a suitable hole 160 mm diameter in the wall similar to a kitchen extractor bonnet...

Page 5: ...e extended from 30 cm to a maximum of 150 cm But for maximum effectiveness and economy we recommend the shortest possible length Warning The length of the exhaust air hose is specially adapted to the...

Page 6: ...sing the room temperature 8 Signal light for dehumidification mode I DOWN button to lower the room temperature 9 Signal light when the water tank is full 10 signal light for active compressor operatio...

Page 7: ...verage operating strength C L Weak operating strength Note In automatic mode the operating strength is set automatically by the unit The operating strength you have just selected is indicated by a sma...

Page 8: ...or Dehumidification mode 8 Remote control All functions and settings as described in points 1 7 above can also be operated adjusted with the remote control supplied The remote control requires two AAA...

Page 9: ...d by the Water Full signal light on the control panel and by a beep To drain the condensation water tank and thereby reactivate the air conditioner please follow the steps below 1 Switch off the air c...

Page 10: ...rate the air conditioner without a filter Stow the air conditioner Empty any condensation water from the condensation tank Let the unit run in ventilation only mode for a few hours to allow it to dry...

Page 11: ...et or a piece of floor mat Furthermore a short exhaust hose for the warm air in the room is advantageous In the event of a defect do not attempt to repair the air conditioner yourself Technical data M...

Page 12: ...assembly instructions Completely or partially dismantled units Conformity The air conditioner has been tested and itself and or parts thereof have been manufactured under the following safety standar...

Reviews: