6.2. 

Determination of a start time: 

 

When the air conditioner is switched off, press the TIMER button to select the desired start time. (A value between 
1 - 24 hours can be selected). After this selected time has elapsed, the unit switches on automatically (with the last 
used settings). 

 

7.  Activation of night mode (low-noise operation) 

 

Press the SLEEP button and the silent night mode is activated. 
 
The activated night mode automatically increases the target temperature by 1°C in the first hour. In the second 
hour, the target temperature is automatically increased by another 1 °C. After that, the target temperature is kept at 
this level. 
 
Furthermore, the night mode always uses the weak operating strength (L). 
 
Pressing the SLEEP key again cancels the silent night mode and reactivates the last selected settings. 
 
Note: After 12 hours of operation in night mode, the air conditioner switches off automatically. In addition, night 
mode cannot be activated in the following operating modes: Automatic mode, Fan mode or Dehumidification mode. 

 

8.  Remote control 

 

All functions and settings as described in points 1 - 7 above can also be 
operated/adjusted with the remote control supplied. 
 
The remote control requires two AAA batteries (not included).  

 

9.  Error display 

 

The air conditioner detects malfunctions and displays them in the unit's display panel. 
If the display field shows "E1", "E3" or "E5", please contact your dealer. 

 

10.  Turbo cooling (increase in cooling capacity) 

 

The air conditioner is equipped with a "turbo cooling function". This increase in cooling capacity can be achieved by 
filling the side water tank of your air conditioner with water once. This provides an additional cooling boost and an 
increase in performance without further energy expenditure !  
See the following graphics for this: 

 

 

 

11.  Other operating instructions 

 

11.1.   To ensure a long service life of the compressor, please do not switch the unit off and on again within 3 

minutes (switching the unit off and then on again shortly afterwards will damage the compressor).  

11.2. 

The cooling circuit (compressor) switches off as soon as the ambient air is below the target temperature. 
However, the air circulation continues. If the ambient air rises above the target temperature, the cooling 
circuit (compressor) also switches on again automatically. 

 
 
 
 

Summary of Contents for WDH-FGA1372

Page 1: ...mproper transport can sometimes occur despite careful instructions on the carton Therefore please let it stand upright for at least 4 hours before using it for the first time so that the refrigerant i...

Page 2: ...sary physical and mental capabilities to operate this unit without problems This air conditioner is only approved for indoor use Only qualified personnel or electricians are allowed to open the unit O...

Page 3: ...sation water 5 water tank compartment 11 air filter 6 water tank compartment display window 12 air filter Accessories 13 exhaust air hose for warm air 14 adapter for connecting the warm air hose with...

Page 4: ...ing This warm exhaust air must be discharged to the outside You can either direct the warm exhaust air outside through a suitable hole 160 mm diameter in the wall similar to a kitchen extractor bonnet...

Page 5: ...e extended from 30 cm to a maximum of 150 cm But for maximum effectiveness and economy we recommend the shortest possible length Warning The length of the exhaust air hose is specially adapted to the...

Page 6: ...sing the room temperature 8 Signal light for dehumidification mode I DOWN button to lower the room temperature 9 Signal light when the water tank is full 10 signal light for active compressor operatio...

Page 7: ...verage operating strength C L Weak operating strength Note In automatic mode the operating strength is set automatically by the unit The operating strength you have just selected is indicated by a sma...

Page 8: ...or Dehumidification mode 8 Remote control All functions and settings as described in points 1 7 above can also be operated adjusted with the remote control supplied The remote control requires two AAA...

Page 9: ...d by the Water Full signal light on the control panel and by a beep To drain the condensation water tank and thereby reactivate the air conditioner please follow the steps below 1 Switch off the air c...

Page 10: ...rate the air conditioner without a filter Stow the air conditioner Empty any condensation water from the condensation tank Let the unit run in ventilation only mode for a few hours to allow it to dry...

Page 11: ...et or a piece of floor mat Furthermore a short exhaust hose for the warm air in the room is advantageous In the event of a defect do not attempt to repair the air conditioner yourself Technical data M...

Page 12: ...assembly instructions Completely or partially dismantled units Conformity The air conditioner has been tested and itself and or parts thereof have been manufactured under the following safety standar...

Reviews: