background image

 

Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany 

www.AKTOBIS.de

 

Email: [email protected] 

 
 
 

Important safety instructions: 
 

 

Operate the unit only in a straight position and with a straight/level stance (Fig. 1) ! 

 

Make sure that no moisture gets into or onto the unit (Fig. 2) ! 

 

Make sure there is a minimum distance of approx. 50 cm to inventory and walls (Fig. 3) ! 

 

Watch out for electricity, never walk into or insert objects into the appliance (Fig. 4) ! 

 

The unit is filled with the flammable refrigerant R290, therefore strictly follow the instructions of this manual and 
read it completely. (Fig. 5) 

 

Do not carry out any repairs on the unit yourself ! (Fig. 5) 

 

Do not place any objects on the appliance and make sure that the air intake and the exhaust air are always 
free! 

 

Supervise the air conditioner when children or animals are near the unit ! 

 

This air conditioner should only be operated by persons who have the necessary physical and mental 
capabilities to operate this unit without problems ! 

 

This air conditioner is only approved for indoor use ! 

 

Only qualified personnel or electricians are allowed to open the unit ! 

 

Only use the recommended voltage for operating the unit ! 

 

Make sure that the power cable is unfolded (untied) before connecting it to the socket ! 

 

Please do not use the power cable as a pull cable for the air conditioner !  

 

Make sure that the plug is cleanly and properly connected to the socket before using the appliance ! 

 

Never reach near the plug or socket with wet hands ! 

 

Make sure that flammable or explosive substances (e.g. gases/oils etc.) are never in the vicinity of the unit ! 

 

If you are not going to use the unit for a long time, switch it off and disconnect the mains plug ! 

 
Please switch off the unit immediately and disconnect it from the mains/power supply if anything 
seems to be wrong ! In this case, please contact a specialist and do not try to repair the unit 
yourself !!! 

 

Examples:

 Fan does not run during operation, fuse has blown or compressor rattles loudly. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

    Fig. 1 

 

 

  Fig. 2   

 

 

   Fig. 3  

 

Fig. 4 

  

 

 
 
 

Fig. 5 

Summary of Contents for WDH-FGA1372

Page 1: ...mproper transport can sometimes occur despite careful instructions on the carton Therefore please let it stand upright for at least 4 hours before using it for the first time so that the refrigerant i...

Page 2: ...sary physical and mental capabilities to operate this unit without problems This air conditioner is only approved for indoor use Only qualified personnel or electricians are allowed to open the unit O...

Page 3: ...sation water 5 water tank compartment 11 air filter 6 water tank compartment display window 12 air filter Accessories 13 exhaust air hose for warm air 14 adapter for connecting the warm air hose with...

Page 4: ...ing This warm exhaust air must be discharged to the outside You can either direct the warm exhaust air outside through a suitable hole 160 mm diameter in the wall similar to a kitchen extractor bonnet...

Page 5: ...e extended from 30 cm to a maximum of 150 cm But for maximum effectiveness and economy we recommend the shortest possible length Warning The length of the exhaust air hose is specially adapted to the...

Page 6: ...sing the room temperature 8 Signal light for dehumidification mode I DOWN button to lower the room temperature 9 Signal light when the water tank is full 10 signal light for active compressor operatio...

Page 7: ...verage operating strength C L Weak operating strength Note In automatic mode the operating strength is set automatically by the unit The operating strength you have just selected is indicated by a sma...

Page 8: ...or Dehumidification mode 8 Remote control All functions and settings as described in points 1 7 above can also be operated adjusted with the remote control supplied The remote control requires two AAA...

Page 9: ...d by the Water Full signal light on the control panel and by a beep To drain the condensation water tank and thereby reactivate the air conditioner please follow the steps below 1 Switch off the air c...

Page 10: ...rate the air conditioner without a filter Stow the air conditioner Empty any condensation water from the condensation tank Let the unit run in ventilation only mode for a few hours to allow it to dry...

Page 11: ...et or a piece of floor mat Furthermore a short exhaust hose for the warm air in the room is advantageous In the event of a defect do not attempt to repair the air conditioner yourself Technical data M...

Page 12: ...assembly instructions Completely or partially dismantled units Conformity The air conditioner has been tested and itself and or parts thereof have been manufactured under the following safety standar...