Set point energy saving
parameter defines what the set point will be when this mode is active and the
Energy saving duration
parameter defines the duration of this mode in hours. It never activates if it is
configured at 0.
This mode may optionally be activated and deactivated whenever you want using the external button connected to one
of the digital inputs, and to do so the corresponding input should be configured as "Remote energy saving”.
COMPRESSOR PROTECTION DELAY (according to model)
This protects the compressor, preventing continuous stops and start-ups in certain exceptional cases.
The
Comrpessor Protection
parameter allows choosing between 2 types of delay:
OFF-ON:
Minimum time the compressor should stay stopped before each start-up.
ON:
Delay time as from when the compressor should activate until it does activate.
The
Protection delay time
parameter defines the time of the previous parameter.
FUNCIONAMIENTO EN CASO DE FALLO EN SONDA 1
If probe 1 fails (failure, disconnection, etc. ), the compressor/solenoid* operates according to the times
programmed in the following parameters:
Compresor ON error s1:
Compressor/solenoid* time in operation in the event of fault in probe 1.
Compresor OFF error s1:
Compressor/solenoid* time stopped in the event of fault in probe 1.
SET POINT LOCKINGS
Using the
Set Point upper limit
and
Set Point lower limit
parameters, it is possible to set a top and bottom limit for
the
Set point (SP)
parameter, which prevents being able to set a set point that is too low or too high that might
damage the installation or the stored product.
STOP COMPRESSOR WHEN THE DOOR IS OPENED
This defines if the compressor/solenoid* will be stopped whenever the cold room's door is opened. To do so, one of
the digital inputs should be configured as "door contact" (See page 25).
If the door stays open longer than the value programmed in the
Inact. with door open
parameter, the
compressor/solenoid* will return to normal operation (See page 25).
ON
Fault in Probe 1
COMP.
OFF
COMP.
OFF
COMP.
ON
COMP.
ON
OFF
COMP.
Time
ON
ON
ON
OFF-ON
SP
SP
SP+Dif.
SP+Dif.
Delay time
Delay
time
OFF
OFF
COMP.
COMP.
Time
Time
*In the panels
AKO-15658
/
15659
, the liquid solenoid is controlled instead of the compressor.
17