ASAHI KASEI
[AK4537]
MS0202-E-04
2005/04
-
53
-
Addr
Register
Name
D7 D6 D5 D4 D3 D2 D1 D0
08H
Timer
Select
0
ROTM ZTM1 ZTM0 WTM1
WTM0 LTM1 LTM0
R/W
RD R/W R/W R/W R/W R/W R/W R/W
Default
0 0 0 0 0 0 0 0
LTM1-0: ALC1
limiter
operation period at zero crossing disable (ZELM bit = “1”) (see Table 25)
The IPGA value is changed immediately. When the IPGA value is changed continuously, the change is done
by the period specified by the LTM1-0 bits. Default is “00” (0.5/fs).
ALC1 Limiter Operation Period
LTM1 LTM0
8kHz
16kHz
44.1kHz
0 0
0.5/fs
63
P
s 31
P
s 11
P
s
Default
0 1 1/fs
125
P
s 63
P
s 23
P
s
1 0 2/fs
250
P
s 125
P
s 45
P
s
1 1 4/fs
500
P
s 250
P
s 91
P
s
Table 25. ALC1 Limiter Operation Period at zero crossing disable (ZELM bit = “1”)
WTM1-0: ALC1 Recovery Waiting Period (see Table 26)
A period of recovery operation when any limiter operation does not occur during the ALC1 operation.
Default is “00” (128/fs).
ALC1 Recovery Operation Waiting Period
WTM1 WTM0
8kHz
16kHz
44.1kHz
0 0
128/fs
16ms 8ms 2.9ms
Default
0 1
256/fs
32ms 16ms 5.8ms
1 0
512/fs
64ms 32ms
11.6ms
1 1
1024/fs
128ms 64ms
23.2ms
Table 26. ALC1 Recovery Operation Waiting Period
ZTM1-0: Zero crossing timeout for the write operation by the
P
P, ALC1 recovery, and zero crossing enable (ZELM
bit = “0”) of the ALC1 operation. (see Table 27)
When the IPGA of each L/R channels perform zero crossing or timeout independently, the IPGA value is
changed by the
P
P WRITE operation, ALC1 recovery operation or ALC1 limiter operation (ZELM bit = “0”).
Default is “00” (128/fs).
Zero Crossing Timeout Period
ZTM1 ZTM0
8kHz
16kHz
44.1kHz
0 0
128/fs
16ms 8ms 2.9ms
Default
0 1
256/fs
32ms 16ms 5.8ms
1 0
512/fs
64ms 32ms
11.6ms
1 1
1024/fs
128ms 64ms
23.2ms
Table 27. Zero Crossing Timeout Period
ROTM:
Period time for ALC2 Recovery operation
0: 2048/fs (Default)
1: 512/fs