Evaporator
Cross flow fan
One-way valve
Main capillary
Filter
Auxillary capillary
Axial flow fan
Condenser
E lectromagnetic
4-way valve
Gas-liquid separator
Compressor
Heating
Cooling
9
Model No.: AC-S10HGX2
Version: 1.0
Cooling system diagram for cooling /heating type
When the power is on, indoor and outdoor units will start to run. When the system operates in cool mode,
the compressor sucks low-temperature, low pressure refrigerant gas from indoor evaporator and then
discharges high-temperature, high-pressure refrigerant gas into outdoor heat exchanger. With the help of
axial flow fan, the gas transfers its latent heat into outdoor air and becomes high-pressure refrigerant
liquid. The liquid is throttled by the capillary and changes into low-temperature and low-pressure liquid
and the flows into indoor heat exchanger. With the help of centrifugal fan, the liquid evaporates into
low-temperature refrigerant gas and indoor air is cooled down. The refrigerant gas is sucked into the
compressor and the cycle introduced above goes on and on, and the demanded low temperature
environment is maintained.
When the system operates in heat mode, 4-way valve changes its way and refrigerant flows into the
reversible cycle as the cool mode. The refrigerant discharges its latent heat in the indoor heat exchanger,
and sucks heat from outdoor heat exchanger and forms the heat pump cycle. This cycle goes on and on
and the demanded high temperature environment is maintained.