Base plate
of outdoor
unit
Outdoor drain elbow
Vacuum
gauge
Valve cap
Liquid
pipe
Gas pipe
Vacuum
pump
31
Model No.: AC-S10HGX2
Version: 1.0
d. Outdoor condensation drainage (Heat pump type only)
i.
When the unit heating or defrosting, the condensing water and defrosting water formed
in the outdoor unit can be drained out reliably through the drain hose.
Installation:
Install the outdoor drain elbow in the
Φ
25 hole on the base plate and joint the drain hose to the
elbow, so that the waste water formed can be drained out to a proper place.
5. Test operation and check after installation
a. Check after installation
Items to be checked
Possible malfunction
Has it been fixed firmly?
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage test?
It may cause insufficient cooling (heating)
capacity.
Is heat insulation sufficient?
It may cause condensation and dripping.
Does the unit drain well?
It may cause condensation and dripping.
Is the voltage in accordance with the rated
voltage marked on the nameplate?
It may cause electric malfunction or damage the
part.
Is the electric wiring and piping connection
installed correctly and securely?
It may cause electric malfunction or damage the
part.
Has the unit been connected to a secure earth
connection?
It may cause electrical leakage.
Is the power cord specified?
It may cause electric malfunction or damage the
part.
Has the inlet and outlet been covered?
It may cause insufficient cooling (heating)
capacity.
Has the length of connection pipes and
refrigerant capacity been recorded?
The refrigerant capacity is not accurate.