![akira AC-S10HGX2 Service Manual Download Page 29](http://html.mh-extra.com/html/akira/ac-s10hgx2/ac-s10hgx2_service-manual_2885936029.webp)
Outdoor unit
Front side plate
Power connection cord
Right side plate
Heat pump type only Heat pump type only
Blue
Red
Brown
Yellow-green
Blue
Brown
Red
Control cord
Control cord
Wire clamp
Wire clamp
Power connection cord
Power connection cord
Torque wrench
Spanner
Joint
Flare nut
Power connection cord
Drain hose
Connection pipe
Wrapping tape
Control cord
(Heat pump type only)
29
Model No.: AC-S10HGX2
Version: 1.0
ii.
Wrap the piping and wiring and pull them through the cut-off tailings hole.
iii.
Hang the mounting slots of the indoor unit on the upper tabs of the rear panel and
check if it is firm enough.
iv.
The height of the installed location should be 2.3m or more from the floor.
4. Install the outdoor unit
a. Install the connection pipe
i.
Align the center of the piping flare with the relevant valve.
ii.
Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench
refer to right figure.
Note: Exceeding tightening torque will damage the flare nut.
Tightening torque table.
Hex nut diameter (mm)
Tightening torque (N.m)
Φ
6
15 ~ 20
Φ
9.5
31 ~ 35
Φ
12
50 ~ 55
b. Electric wiring connection
i.
Disassemble the front side plate of outdoor unit.
ii.
Get through the wire hole of outdoor unit, cover the cable-cross loop.
iii.
Disassemble the wire clamp, fixing the power connection cord on the terminal of line
bank.
iv.
Use the wire clamp to fix the power connection cord and control cord, then connect the
corresponding connector.
v.
Make sure that the wiring has been connected firmly.
vi.
Reassemble the front side plate.