![akira AC-S10HGX2 Service Manual Download Page 27](http://html.mh-extra.com/html/akira/ac-s10hgx2/ac-s10hgx2_service-manual_2885936027.webp)
Wrenched
Bent
Flooded
Right
Right
Left
Left rear
Low left
Low right
27
Model No.: AC-S10HGX2
Version: 1.0
b. Install the piping hole
i.
The direction of piping can be chosen from six directions.
ii.
Make the piping hole (
Φ
55) in the wall at a slight downward slant to the outdoor side.
iii.
Insert the piping-hole sleeve into the hole to prevent the connection piping and wiring
from being damaged when passing through the hole.
c. Install the drainage hole
i.
For well draining, the drain hose should be placed at a downward slant.
ii.
Do not wrench or bend the drain hose or flood its end by water.
iii.
When the long drainage hose passing through indoor, should wrap the insulation
materials.
d. Install the connection pipes
i.
Connect the connection pipes with the relevant union pipes of the indoor unit. Tighten
the nut of the connection pipe joint. (Please refer to “Installation the connection pipe”).
Note:
i.
Connect the connection pipes with the indoor unit firstl and the outdoor unit secondly.
ii.
Be careful in bending the connection pipes, or you will damage the pipes.
iii.
If the tightening torque is too great in tightening the flare nuts, leakage will happen.