∎ Insert 3-way valve after its handle is fully turned counterclockwise.
∎ Turn the 3-way valve handle clockwise slowly. Stop turning it when the
needle of the gauge starts to move. If it is turned clockwise too tightly,
the valve may easily be damaged. Pay special attention to ensure that
the nitrogen gas is not charged excessively.
ONLY FILL WITH N
2
GAS!
GAS CHARGE PRESSURE : 6.8kg/㎠(97 PSI)
CAUTION - THIS VESSEL CONTAINS HIGH PRESSURE GAS.
REMOVE REMAINING GAS BEFORE DISASSEMBLY.
ONLY FILL WITH N
2
GAS!
GAS CHARGE PRESSURE : 16.5kg/㎠(235 PSI)
CAUTION - THIS VESSEL CONTAINS HIGH PRESSURE GAS.
REMOVE REMAINING GAS BEFORE DISASSEMBLY.
∎ Back head sticker symbol
- Appears on the back head charging valve