63
Pin No.
Pin Name
I/O
Description
53 ~ 55
NC
–
Not used (PLL UP).
56
SLF
–
Not used (PLL UP).
57
SLR
–
Not used (PLL UP).
58
TEMP
I
S-8110AMP OUT signal input pin.
59
MAGIC
–
Not used (PLL UP).
60
NC
–
Not used (PLL UP).
61
TEST
–
Not used (PLL UP).
62
DISCPRO
I
Input pin for prevention of DISC error erase SW.
63
MNT3
I
Monitor signal input pin 3 for CXD2652AR.
64
MNT2
I
Monitor signal input pin 2 for CXD2652AR.
65
MNT1
I
Monitor signal input pin 1 for CXD2652AR.
66
MNT0
I
Monitor signal input pin 0 for CXD2652AR.
67
SENS
I
Input SENS signal for CXD2652AR.
68
FLG
I
Monitor FLAG included in SRDT of CXD2652AR interface.
69 ~ 70
NC
–
Not used.
71
P-CONT
–
Not used.
72
RFSW
–
Not used.
73 ~ 74
NC
–
Not used.
75
DQSY
I
Synchronize input pin for digital-in SUB-Q.
76
XINT
I
Status synchronize input pin for CXD2652AR.
77
SRDT
I
Serial data input pin for CXD2652AR interface.
78
SWDT
O
Serial data output pin for CXD2652AR interface.
79
SCLK
O
Serial clock output pin for CXD2652AR interface.
80
SQSY
I
SUB-Q, ADIP synchronize input.
81 ~ 83
NC
–
Not used.
84
TXI
–
Connected to VSS.
85
TXO
–
Open. (Not used)
86
VSS
–
Connected to VSS.
87
VDD
–
Connected to VDD.
88
NC
–
Connected to VDD.
89
NC
–
Not used.
90
DRVMUTE
O
Outputs MUTE signal for BA5970FP.
91 ~ 94
NC
–
Not used.
95
RECP
O
Laser power switch signal output pin.
96
TX
O
Output permission signal of record data output.
97
MOD
O
Output ON/OFF signal for high frequency modulation circuit.
98
OPMUTE
O
Laser MUTE signal output pin.
99
ARST
O
AK4516VF reset signal output pin.
100
DENF
O
De-emphasis ON/OFF signal output pin.
Summary of Contents for CSD-MD50
Page 16: ...18 17 FL 16 ST 32GNK GRID ASSIGNMENT ANODE CONNECTION...
Page 17: ...20 19 BLOCK DIAGRAM 1 MAIN...
Page 18: ...22 21 BLOCK DIAGRAM 2 SYSTEM CONTROL...
Page 19: ...24 23 BLOCK DIAGRAM 3 MD...
Page 20: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D E F G H I J K 26 25 WIRING 1 MAIN...
Page 21: ...28 27 SCHEMATIC DIAGRAM 1 TUNER...
Page 22: ...30 29 SCHEMATIC DIAGRAM 2 DECK...
Page 23: ...32 31 SCHEMATIC DIAGRAM 3 MAIN...
Page 24: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D E F G H I J K 34 33 WIRING 2 SYSTEM CONTROL CD...
Page 25: ...36 35 SCHEMATIC DIAGRAM 4 SYSTEM CONTROL...
Page 26: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D E F G H I J K 38 37 WIRING 3 FL KEY...
Page 27: ...40 39 SCHEMATIC DIAGRAM 5 CD...
Page 28: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 A B C D E F G H I J K 42 41 WIRING 4 POWER...
Page 29: ...44 43 SCHEMATIC DIAGRAM 6 FL KEY POWER...
Page 31: ...48 47 SCHEMATIC DIAGRAM 7 MD...
Page 54: ...72 IC BLOCK DIAGRAM IC BA5970FP IC BA6417F...
Page 55: ...73 IC BD7910FV IC BH3862FS...
Page 56: ...74 IC AK4519VF IC AK93C65AF...
Page 57: ...75 Rog CURRENT DETECTOR TERMINAL IC BA5936 IC LC75710NE...
Page 58: ...76 VSSX VSSD VDD VSSA IC TC74HCT7007AF IC LC72121...