36
Subject to technical amendments without prior notice | 83059300iUK | ait-deutschland GmbH
Sheet
Page
=MA1
+SS1
Keys
1
0
7
6
8
9
3
11
4
4
2
5
8
/
831218a
ait-deutschland GmbH
Industriestraße 3
95359 Kasendorf
Germany
MAP
Checked by
Changed on
28.03.2022
3311kafu
08.03.2022
Creator
Created on
Changed by
KAF
Item no
817472a
Circuit diagram
Install. Nr
&EFS
Refer to protection notice ISO 16016.
HSV9M-1/3
Doc. no.
Revision
a
Heating pump
Contactor for Electric heating element
Power supply compressor
Power supply WP
Controller board; Attention: I-max = 6,3A/230VAC
Machinery room
M5
Q5
K10
X8
X100
+MR1
Power supply control
MOD-BUS
Energy supplier contact; closed on release; bridge if no blocki
ng interval
XSE
Sensorcard
X200
X10
EVU
K11
Control unit
R3
Domestic hot water temperature sensor
R4
Return sensor
R5
Flow sensor
Encoding resistor; HDT6LWD 13,3kOhm; HDT9LWD 14,7kOhm
R9
WK11-1
Connection cable control panel
XSH
Shield clamp Control unit
Equipement
Description
UK 817472a
STB
Temperature shutdown Electric heating element
X300
Power supply controller 230V
X400
Power supply electric heating element
X20
Terminal board, Modbus
X9
Power supply electric heating element
E22
Electric heating element
WK11-2
Connection cable control panel
WX400
Connection Electric heating element
Y1
Domestic hot water valve
Circuit diagram 4/4
HSV…
Summary of Contents for HSDV 12.1M3
Page 1: ...UK 83059300iUK Accessories for heat pumps Operating Manual Hydraulic Station...
Page 41: ...41 Subject to technical amendments without prior notice 83059300iUK ait deutschland GmbH...
Page 42: ...42 Subject to technical amendments without prior notice 83059300iUK ait deutschland GmbH...
Page 43: ...43 Subject to technical amendments without prior notice 83059300iUK ait deutschland GmbH...
Page 44: ...UK ait deutschland GmbH Industriestra e 3 D 95359 Kasendorf www ait deutschland eu...