Manual_Version 2.00(20070416)
91
DIUR Relay Characteristics
1. Coil Ratings
Rated voltage
3 VDC
Rated current
50 mA
Coil resistance
60 W
Coil inductance: Armature OFF
0.05
(H) (Ref. value): Armature ON
0.11
Must operate voltage
80% max. of rated voltage
Must release voltage
10% min. of rated voltage
Max. Voltage
200% of rated voltage at 23
°
C
Power consumption
Approx. 150 mW
2. Contact Ratings
Load
Resistive load (cosf = 1)
Rated load
0.5 A at 125 VAC; 1 A at 24 VDC
Contact material
Ag + Au-clad
Rated carry current
2 A
Max. Switching voltage
125 VAC, 60 VDC
Max. Switching current
1 A
Max. Switching power
62.5 VA, 30 W
Failure rate (reference value)
1 mA