INTRODUCTION

" When the HCFC fluids are replaced, these appliance have been
optimized to operate with the R-407C coolant which contains no
chlorine and has no effect on the ozone layer."

1. DEFINITION

The 

X 1100

 

 and 

X 1900

 

packaged air conditioners

are presented :
• Single packaged for the 

WATER

 

 cooled models

(

AO

),

• with a separate outdoor condensing unit for the

AIR

 cooled models (

AR

).

The air intake and discharge is provided :
• either directly by air intake grilles and a discharge

plenum (accessory),

• or by ducts for intake and/or discharge, to be

connected to the connection flanges (accessory).

This well-finished, single packaged unit combines
many features such as east installation, high efficiency,
quiet operation and reliability, which make it well suited
for air conditioning, dehumidification and air filtering
in offices, stores and industrial premises.

These packaged air conditioners can be equipped
with the following accessories :
• Electric heater (integrated or in ducts),
• Hot water coil,
• Fresh air intake (lateral or rear),
• Remote control,
• Air discharge plenum with remote control.

They benefit from 30 years experience and are
perfectly suited to working with :
• Wasted water; its consumption being reduced to a

minimum by a pressure valve (included in the 

AO

-

wasted water model).

• Recycled water; supplied by a cooling tower or an

outdoor heat exchanger.

• Outside air; with the possibility of operating at very

low temperatures (down to –10°C with the “ALL
SEASONS” option on the 

AR

 

models).

2. MAIN DATA

• Cabinet with reduced floor dimensions,
• Standard ventilation :

Three fan speeds (high/normal/low) which can be
pre-selected on the terminal block to adapt to the
installations aeraulic pressure losses.

• Equipment option of “High Speed Ventilation” with

a single speed motor.

• Vertical discharge with or without duct, or horizon-

tal discharge with plenum (accessory).

• Two air intake possibilities :

On the front with grilles or on the rear with ducts,
with the rear air intake (accessory).

• M1 flame retardant filters, mounted on a metal frame

with stiffening netting.

• Integrated unit controls (Control Panel) or remote

control (accessory).

• Electrical, water and refrigerant pipe connections

on the right or left side.

• Cooling with wasted water with a pressure valve or

recycled water without a valve.

• Possibility of running in Cooling mode down to an

outdoor temperature of –10° C for the 

AR

 models

with the “ALL SEASONS” accessory.

• Two heating possibilities (accessories) :

Integrated electric coils or hot water heating coils

• Three control possibilities :

Inverting type (standard), automatic thermostat for
“heating/cooling” with neutral zone (accessory
supplied with integrated electric heating) and air
monitoring control (remote control accessory).

• Two refrigerant connection pipe possibilities (

AR

models): up to 25 m maximum with factory pre-
charged pipes (accessory) or with pipes brazed and
charged on site (set of female valves supplied as
an accessory for connections up to 45 m).

3. DESCRIPTION

3.1 Bodywork

• Panels and side faces made of profiled sheet steel

covered with enamel finish, baked in a high
temperature oven.

• Intake grilles made of modular elements in

flameproof, shock resistant polystyrene, classified
UL-VO according to UL94.

3.2 Insulation and protection

3.2 Insulation and protection

3.2 Insulation and protection

3.2 Insulation and protection

3.2 Insulation and protection

• Thermal and acoustic insulation of the unit.
• Watertight unit base for the possible collection of

condensates or abnormal overflowing (e.g.
condensate drain tray clogging).

3.3 Refrigerant circuit

• All models

– Hermetic type compressor fitted with thermal and

electrical protections, liked to a factory sealed
and brazed cooling circuit.

– Pressostats and high and low pressure measu-

rement Schrader valves.

– Liquid circuit protected by a strainer (

AO

 model)

or by a filter (

AR

 model)

– Copper tube evaporator with aluminium fins and

anti-corrosion protected condensate tray.

· AO Model

– Coaxial condenser with counter flow circulation,

equipped with finned copped tube in a steel cover.

– Pressure valve on the water inlet for reducing water

consumption to a minimum (wasted water model).

– On request, the unit is supplied without a pres-

sure valve but with an additional Schrader valve
connection for independent control of the water
flow (recycled water model).

Summary of Contents for X 1100 AO

Page 1: ...1 VERTICAL UNITS X 1100 X 1900 air cooled AR water cooled AO PACKAGED AIR CONDITIONERS Technical Data 99TX11 ...

Page 2: ...eatment unit 17 DIMENSIONS INSTALLATION Outdoor condensing unit 18 REFRIGERATION PIPEWORK Model AR 19 ELECTRICAL CONNECTIONS Main power supply 20 ELECTRICAL SPECIFICATIONS Main power supply 21 MODELS VOLTAGE NOT INTERCHANGEABLE CODE NUMBERS Indoor unit Outdoor unit 3N 400V 50 Hz 3 230V 50 Hz X 1100 R 407C X 1900 R 407C UC 33A X 1100 UC 53A X 1900 AR with air cooled separated condenser 7XU022082A 7...

Page 3: ...grated unit controls Control Panel or remote control accessory Electrical water and refrigerant pipe connections on the right or left side Cooling with wasted water with a pressure valve or recycled water without a valve Possibility of running in Cooling mode down to an outdoor temperature of 10 C for the AR models with the ALL SEASONS accessory Two heating possibilities accessories Integrated ele...

Page 4: ... on the liquid line AR model Crankcase heater as standard on the air cooled models Protection of the UC fan motor with internal ther mostat Mains power supply 3 N 400 V 50 Hz as stan dard and 3 230 V 50 Hz as an option Terminal block for single phase 230 V power supply to the control circuit with a 400 V 230 V transfor mer not supplied if the neutral wire is not available 3 6 Control Regulation Fa...

Page 5: ... x Height packed mm mm 890 x 430 x1540 940 x 495 x 1690 1000 x 500 x1735 1050 x 565 x 1890 Weight net packed kg 136 145 151 160 182 195 199 212 DISCHARGE PLENUM Width x Depth x Height net Width x Depth x Height packed Weight net packed mm mm kg 890 x 430 x 220 1020 x 550 x 340 10 12 1000 x 500 x 260 1120 x 620 x 380 13 15 OUTDOOR CONDENSING UNIT UC Width x Depth x Height net Width x Depth x Height...

Page 6: ...891 9512 9134 8756 8377 19 PT W 11271 10879 10486 10093 9700 9307 8914 PA W 3280 3485 3690 3895 4100 4305 4510 21 PS W 4738 4841 4944 5047 5150 5253 5356 23 5630 5753 5875 5998 6120 6242 6365 25 6523 6665 6806 6948 7090 7232 7374 27 7415 7576 7738 7899 8060 8221 8382 29 8308 8488 8669 8849 9030 9211 8914 31 9200 10571 10474 10093 9700 9307 8914 21 PT W 11936 11523 11111 10699 10287 9874 9462 PA W ...

Page 7: ...11022 11261 11501 11740 11980 12220 12459 27 12512 12784 13056 13328 13600 13872 14144 29 14002 14307 14611 14916 15220 15544 14888 31 17655 17655 17493 16856 16200 15544 14888 21 PT W 19934 19245 18557 17868 17180 16491 15803 PA W 5649 5997 6345 6693 7041 7389 7738 23 PS W 7325 7484 7644 7803 7962 8121 8281 25 8906 9099 9293 9486 9680 9874 10067 27 10486 10714 10942 11170 11398 11626 11854 29 120...

Page 8: ...pressure kPa 15 20 35 21 PS W 6625 23 7728 25 8831 27 9935 29 11031 31 11031 19 PT W 11700 Water consumption l h 598 700 923 PA W 3350 Water pressure kPa 16 22 38 21 PS W 4990 23 6160 25 7330 27 8500 29 9670 31 10840 21 PT W 12411 Water consumption l h 631 739 974 PA W 3475 Water pressure kPa 18 25 43 23 PS W 4373 25 5614 27 6855 29 8097 31 9338 33 10579 23 PT W 13133 Water consumption l h 665 779...

Page 9: ...19086 Water consumption l h 856 1003 1322 PA W 5508 Water pressure kPa 24 33 58 23 PS W 6881 25 8790 27 10698 29 12607 31 14516 33 16424 23 PT W 20182 Water consumption l h 903 1057 1394 PA W 5751 Water pressure kPa 27 37 65 25 PS W 5807 27 7825 29 9843 31 11861 33 13879 BS Dry bulb temperature C BH Wet bulb temperature C PT Total cooling capacity W PA Power absorbed by the compressor W without fa...

Page 10: ...1969 25 8831 13664 27 9935 15359 29 11031 16950 31 11031 16950 19 PT W 11700 18000 Outlet water temperature C 35 35 PA W 3350 5300 21 PS W 4990 7800 23 6160 9600 25 7330 11400 27 8500 13200 29 9670 15000 31 10840 16800 21 PT W 12411 19086 Outlet water temperature C 35 36 PA W 3475 5508 23 PS W 4373 6881 25 5614 8790 27 6855 10698 29 8097 12607 31 9338 14516 33 10579 16424 23 PT W 13133 20182 Outle...

Page 11: ...tandard ventilation VS Motor 0 3 kW High ventilation FV Motor 0 43 kW VENTILATION GV High VN Normal VR Red FV High Rotational speed motor propeller R P M 1000 850 670 1360 Available pressure daPa nominal 14 0 0 20 maximal 20 13 4 25 Power input W 510 405 260 570 ÉQUIPEMENT DE VENTILATION Ventilation Standard VS Moteur 0 43 kW Forte Ventilation FV Moteur 1 kW VENTILATION GV Grande VN Normale VR Réd...

Page 12: ...ter outlets Models AO AR MODELS X 1100 X 1900 CONDENSATE WATER DRAINING HOSE mm Ø 20 x 25 BOTTOM TRAY OUTLET for hose Ø 20 x 25 mm Ø 7 8 Ø 22 mm out WATER SUPPLY WASTED WATER RECYCLED WATER MODELS X 1100 X 1900 X 1100 X 1900 NOMINAL WATER FLOW Air to be treated 27 C 47 m3 h 0 70 0 95 2 1 3 05 Nominal water temperature Inlet C Outlet C 15 26 32 WATER PRESSURE Minimum kPa Maximum kPa 50 1000 1000 Co...

Page 13: ...emperature Tw Difference in temperature water inlet outlet Twm Hot water average temperature Pw Hot water pressure drops WATER FLOW Qw m3 h Water flow Nominal flow K1 C FFICIENT AIR FLOW Qa Qn K1 0 80 0 90 1 1 1 1 2 0 87 0 95 1 1 06 1 13 K2 COEFFICIENT Tw Tw K 4 6 8 10 12 14 16 18 20 K2 1 05 1 03 1 01 1 0 98 0 96 0 95 0 94 0 92 X 1100 X 1900 Capacity l 2 3 Nominal water flow m3 h 1 3 2 6 Maxi wate...

Page 14: ... 76 issued by the L N E PARIS 2 Test report 82 18176 dated 12 05 82 INTAKE DISCHARGE ELECTRICAL HEATER HOT WATER COIL ACCESSORIES Marks Models X 1100 X 1900 1 HOT WATER COIL Nominal power input Nominal water flow Water pressure loss kW m3 h kPa 15 5 1 3 10 29 7 2 6 22 Ø Connections mm M 26 x 34 2 ELECTRICAL HEATER Total power input Number of stages Number of elements Power input element kW kW 9 1 ...

Page 15: ...ff 1 On Heating Ambient thermostat type inverting thermostat included with neutral zone accessory 1 CONTINUOUS FAN OPERATION FOR HEATING AND COOLING VA Fan operation is continuous in both HEATING and COOLING modes Terminal A of the REMOTE CONTROL unit must be connected to the termi nal 7 on the air conditioner VA wiring 2 ON OFF FAN OPERATION IN HEATING MODE AND CONTINUOUS OPERATION IN COOLING MOD...

Page 16: ...chassis Hot water coil accessory Electric heater accessory Direct discharge cooling coil Evaporator Filter mounted on sliding rails fresh air and air intake Condensate tray Condensate drain hose Hermetically sealed compressor Air discharge connection flange accessory Air intake connection flange accessory Control panel Hot water coil connections and bleed Access on the right and left side Air inta...

Page 17: ...EAR VIEW REAR VIEW DIMENSIONS INSTALLATION Air treatment unit Models X 1100 X 1900 A 220 260 B 1540 1735 C 890 1000 D 430 500 E 834 944 F 404 474 G 515 580 H 220 260 J 471 542 K 168 180 L 210 270 M 140 155 N 410 460 P 750 860 Q 22 32 R 182 295 S 226 173 T 105 192 U 208 273 V 264 271 CLEARANCES mm FRONT REAR LATERAL DISCHARGE INTAKE SIDE Vertical Plenum Front Rear Conn Oppos 650 1200 650 650 Dimens...

Page 18: ...ith low outdoor temperatures down to 10 C for air conditioning of rooms with high internal heat gains It comprises 1 pressure controller Low speed off ref EA 21 1 pressure controller Low high speed ref EA 22 1 drop resistor ref RH 1 low pressure timer ref EB 21 References on wiring diagram Dimensions in mm 7 7 Air flow m3 h 3700 5000 Rotational speed ventilation R P M 650 630 Sound pressure at 10 ...

Page 19: ...er m above 2 ml REFRIGERATION PIPEWORK Model AR Minimum slope downwards 1 cm m Discharge Line Liquid Line X 1100 X 1900 Air treatment Model AR g 1013 1704 Condensing units UC 33A UC 53A g g 3237 3796 Precharged linking pipes maxi length 25 m Discharge line Liquid line charge Ø charge Ø g m 1 2 precharge 3 8 55 Model AO indoor unit 1260 2850 NOTES For pipes between 25 and 45 m long made on the site...

Page 20: ...NIT UC Models AR X 1100 X 1900 UC 33 A UC 53 A INTERCONNECTIONS WITH REMOTE CONTROL ELECTRICAL CONNECTIONS Main power supply 3 230 V 50 Hz 3 400 V 50 Hz 3 400 V 50 Hz 230 V 50 Hz Ventilation Cooling continuous ventilation with cooling no ventilation control Ventilation Cooling or Heating VA Continuous ventilation with cooling heating VB Ventilation adjusted for heating and continuous cooling and V...

Page 21: ...r fuse rating Cable size kW A A A A mm2 9 4 9 6 25 5 26 2 30 31 60 61 32 4 x 4 9 4 9 6 25 5 26 2 30 31 58 59 32 4 x 4 9 4 9 6 15 5 16 2 19 20 38 39 20 5 x 2 5 9 4 9 6 15 5 16 2 19 20 37 38 20 5 x 2 5 12 5 13 33 7 34 2 40 43 106 110 40 45 4 x 10 12 5 13 33 7 34 2 40 43 103 107 40 45 4 x 10 12 5 13 20 4 20 9 24 27 60 64 25 32 5 x 4 12 5 13 20 4 20 9 24 27 57 61 25 32 5 x 4 Cooling Ventilation VS FV ...

Page 22: ...GmbH DEUTSCHLAND Berner Straße 43 60437 FRANKFURT MAIN Tel 0 69 507 02 0 Fax 0 69 507 02 250 www airwell de Itelco Clima Srl ITALY Via Montefeltro 4 20156 MILANO Tel 02 334 219 1 Fax 02 334 219 33 www itelco clima com Iber elco s a SPAIN Ciències 71 81 Mòdul 5 POLIGONO PEDROSA 08908 L HOSPITALET DE LLOBREGAT Tel 34 93 335 04 44 Fax 34 93 335 95 38 www iberelco es ...