AN
COMPANY
‹
#
›
Auto Mode/ Fan Mode
In AUTO mode, the system selects the running mode (COOL/HEAT/FAN) automatically according to
the room temperature. The display shows the actual running mode and setting temperature. There
will be 30s delay for mode conversion.
1. When RAT≥25, the cooling mode is selected.
2. When RAT≤22, the unit runs in heating mode
3. When 22 <RAT< 25, upon initial startup, the unit will enter auto mode and run in automatic fan
mode. If the other mode changes into auto mode, the previous running mode will remain.
Model 09/12/18/24
22 c
25 c
RAT
Heating Mode
Auto Fan Mode
Cooling Mode
In this mode, the indoor fan may run at high, medium, low and automatic speed. The compressor, outdoor
fan and 4-way valve will be OFF.
In this mode, the range of setting temperature is 16~30C.
Fan Mode
Summary of Contents for HDD 009
Page 1: ...AN COMPANY HDD HED Training Presentation Presented By Yossi Emquies Jan 12th 2011...
Page 5: ...AN COMPANY Specifications...
Page 6: ...AN COMPANY Out Line Dimensions Model 09 12 Indoor Unit Outdoor Unit...
Page 7: ...AN COMPANY Out Line Dimensions Model 18 24 Indoor Unit Outdoor Unit...
Page 8: ...AN COMPANY TECHNICAL ASPECTS...
Page 13: ...AN COMPANY Refrigerant Diagram Model 09...
Page 14: ...AN COMPANY Refrigerant Diagram Model 12...
Page 15: ...AN COMPANY Refrigerant Diagram Model 18...
Page 16: ...AN COMPANY Refrigerant Diagram Model 24...
Page 17: ...AN COMPANY Wiring Diagram IDU INDOOR 09 12 INDOOR 18 24...
Page 18: ...AN COMPANY Wiring Diagram ODU OUTDOOR 09 12 OUTDOOR 18 24 EEV is only for Model 24...
Page 28: ...AN COMPANY Main Control Functions...
Page 36: ...AN COMPANY Sleep Mode...
Page 37: ...AN COMPANY Clean Function and I Feel Mode Clean Function I Feel Function...
Page 42: ...AN COMPANY 9 12 Deicing Procedure Protections 18 24 models...
Page 45: ...AN COMPANY Test Mode Procedure Models 9 12...
Page 46: ...AN COMPANY Test Mode Procedure Models 18 24...
Page 47: ...AN COMPANY Forced Cooling Mode 18 24 Models Only...
Page 54: ...AN COMPANY END...