Fault Checkup

Please check the following when consigning repair service:

                     Symptoms                                                     Reasons

All these  are not problems

•  Water flow sound

Water flow sound can be heard when starting operation, 

during operation or immediately after stopping operation. 

When it starts to work for 2-3 minutes, the sound may 

become louder, which is the flowing sound of refrigerant or 

the draining sound of condensed water.

•  Cracking sound

During operation, the air conditioner may make the 

cracking sound, which is caused from the temperature 

changes or the slight dilation of heat exchanger.

•  Terrible smell in outlet air

•  Flashing operating 

indicator

When switching it on again after power failure, turn on the 

manual power switch and the operating indicator flashes.

•  Awaiting indication 

It displays the awaiting indication as it fails to perform 

refrigerating operation while other indoor units are 

in heating operation. When the operator set it to the 

refrigerating or heating mode and the operation is opposite 

to the setting, it displays the awaiting indication.

•  Sound in

•  shutdown indoor 

•  unit or white 

•  steam or cold air

To prevent oil and refrigerant from blocking the shutdown 

indoor units, refrigerant flows in the short time and make 

the sounds of refrigerant flowing. Otherwise, when other 

indoor units performs heating operation, white steam may 

occur; during refrigerating operation, cold air may appear.

When the conditioner is powered on, the sound is made 

due to the resetting of the expansion valve.

Check if it is in the state of Timer-ON and Timer-OFF.

•  Failure to work

Check if there is a power failure.

Check if the manual power switch is turned off.

Check if the supply fuse and breaker are disconnected.

Check if the protective unit is working.

Check if refrigerating and heating functions are selected 

simultaneously with the awaiting indication on line control.

•  Bad cooling & heating 

effects

Check if air intake port and air outlet port of outdoor units are 

blocked.

Check if the door and windows are open.

Check if the filtering screen of air cleaner is blocked with 

sludge or dust.

Check if the setting of wind quantity is at low wind.

Check if the setting of operation is at the Fan Operation state.

Check if the temperature setting is proper.

During operation, the air conditioner may make the cracking 

sound, which is caused from the temperature changes or 

the slight dilation of heat exchanger.

Under the following circumstances, immediately stop the operation, disconnect the manual 

supply switch and contact the after-service personnel. 

•  When buttons are inflexible actuated;

•  When there are foreign objects and water in the refrigerator;

•  When it cannot still be operated after removing the operation of protective unit;

•  When other abnormal conditions occur.

Please make another check.

•  Clicking sound when 

switching the air condition 

on

•  Start or stop working 

automatically

Summary of Contents for AWSI-DDV007-N11

Page 1: ... Unit Operation Installation Manual AWSI DDV007 N11 AWSI DDV009 N11 AWSI DDV012 N11 AWSI DDV016 N11 No 0150524401 Please read this manual carefully before using Keep this operation manual for future reference ...

Page 2: ... 12 Test Run Failure Code 18 Operating Range of Air Conditioner Cooling dry Indoor Max DB 32 C WB 23 C Min DB 18 C WB 14 C Outdoor Max DB 43 C WB 26 C Min DB 5 C Heating Indoor Max DB 27 C Min DB 15 C Outdoor Max DB 21 C WB 15 C Min DB 15 C Warning If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This ...

Page 3: ...1 Parts and Functions ...

Page 4: ...fire When installing or moving the unit the refrigerant system should be vacuumed and recharged with R 410A refrigerant If any other gas enters the system it may lead to abnormal high pressure which may cause damage or injury Please use the proper manifolds or branches during the system installation The wrong parts may cause refrigerant leakage Keep the drain pipe away from toxic gas vents to prev...

Page 5: ...ected to the gas pipe water pipe lightening rod or the telephone grounding wire Improper grounding may cause electric shock The Circuit Breaker should be installed If not it may cause electric shocks After installation the air condition equipment should be powered on and passed the electric leakage current lest ...

Page 6: ...ration immediately after power on can result in severe damage to internal parts Turn off the power to save energy if the unit will be not used for a long period If the unit is not powered off it will consume power 3 minutes protection To protect the unit compressor can be actuated with at least 3 minutes delay after stopping Close the window to avoid outdoor air getting in Curtains or window shutt...

Page 7: ...r conditioner operates in the environment with too much dust clean the air conditioner more times generally once every two weeks Do not wipe the wind deflector with water forcibly to avoid falling off Cleaning Wind Deflector Cleaning the air outlet port and the shell Attention Don t use gasoline benzene diluents polishing powder or liquid insecticide to clean them Do not clean them with hot water ...

Page 8: ... occur during refrigerating operation cold air may appear When the conditioner is powered on the sound is made due to the resetting of the expansion valve Check if it is in the state of Timer ON and Timer OFF Failure to work Check if there is a power failure Check if the manual power switch is turned off Check if the supply fuse and breaker are disconnected Check if the protective unit is working ...

Page 9: ...ation where the outlet air can be spread to places all over the house and arrange proper locations for connecting pipes and lines as well as the drainpipe to the outdoor 3 Ceiling construction must be hard enough to hold the weight of the unit 4 Make sure that the connecting pipe the drainpipe and connecting guide line can be put into walls to connect the outdoor units 5 It is recommended to make ...

Page 10: ...please consult with indoor decoration personnel about actual conditions a Ceiling reinforcement To ensure the ceiling is horizontal and will not shake the ceiling base frame must be reinforced b Cut off and remove the ceiling base frame c Reinforce the end faces left when the ceiling is removed and further reinforce the base frame that fix both ends of the ceiling d After the body installation is ...

Page 11: ...nnected to air return shutter as shown in Fig 1 3 Heat Preservation of Blast Pipes Heat preservation lays should be provided for air blowing return pipes Paste glue nails on the blast pipes and attach thermo wool which covered by a layer of silver paper fix it with glue nail cover and then seal the joint with silver paper Selection of fan outlet when a high performance filter is used The fan has r...

Page 12: ... avoid the pipe connections getting loose or off Drain hose should not be pulled out laterally for more than 20cm and should be supported every 0 8 1 0m to avoid bending 6 The end of drain hose should be more than 50mm away from the ground or the bottom of drainage tank It should not be put in water To directly drain condensate into drainage ditch the drain hose must be U shaped to avoid stink spr...

Page 13: ...ng or flare opening is broken Vacuumize from the stop valve of outdoor units with vacuum pump Refrigerant sealed in indoor machine is not allowed to use for vacuumization Vacuum pump with check valve should be used for vacuumizing to prevent pump oil flowing into the machine Open all the valves of outdoor units NB oil balancing stop valve must be shut up completely when only connected one main uni...

Page 14: ...ve wire and plug N connected to null wire while should be connected to the ground wire For the type with auxiliary electrically heating function the live wire and the null wire should not be misconnected or the surface of electrical heating body will be electrified If the power line is damaged replace it by the professional personnel of the manufacturer or service center The power line of indoor u...

Page 15: ...W01 on the main unit of wired control is set to 0 while SW01 on other sub units of wired control are set to 1 2 3 and so on in turn Please refer to the code setting A at page 15 B One wired control controls one indoor unit as shown in the above figure indoor unit 6 19 The indoor unit and the wired control are connected via three lines with polarity C Two wired controls control one indoor unit as s...

Page 16: ...nsions 100 0 3mm2 x core shielding lin 300 and 400 1 25mm2 x core shielding lin 100 and 200 0 5mm2 x core shielding lin 400 and 600 2 mm2x core shielding lin 200and 300 0 75mm2 x core shielding lin The shielding lay of the signal line must be grounded at one end The total length of the signal line shall not be more than 600m Items Total Current of Indoor Units A Cross Section mm2 Length m Rated Cu...

Page 17: ... group address 0 0 0 0 wire controlled master unit default 0 0 1 1 wire controlled slave unit 0 1 0 2 wire controlled slave unit 0 1 1 3 wire controlled slave unit 1 0 0 4 wire controlled slave unit 1 0 1 5 wire controlled slave unit 1 1 0 6 wire controlled slave unit 1 1 1 7 wire controlled slave unit SW01_5 SW01_6 SW01_7 SW01_8 Capability of indoor unit 5 6 7 8 Capability of indoor unit 0 0 0 0 ...

Page 18: ...ess Note 2 2 3 4 5 6 7 8 Address of indoor unit Address of centralized controller 0 0 0 0 0 0 0 0 Default 0 Default 0 0 0 0 0 0 1 1 1 0 0 0 0 0 1 0 2 2 0 1 1 1 1 1 1 63 63 1 0 0 0 0 0 0 0 64 1 0 0 0 0 0 1 1 65 1 0 0 0 0 1 0 2 66 1 1 1 1 1 1 1 63 127 SW08_1 WiFi Control Mode Option 1 Single Control 0 Group Control SW08_2 Passive contact OEM total heat exchanger linkage 1 Generally passive contact i...

Page 19: ...ON Display ambient temperature OFF OFF Do not display ambient temperature SW4 ON 26ð lock disabled ON OFF 26ð lock enabled SW5 ON Collect ambient temperature of wired controler ON OFF Collect ambient temperature of PCB SW6 ON Power failure memory disabled OFF OFF Power failure memor enabled SW7 ON Temperature sensor 4k7 enabled ON Betewwn SW7 and SW8 one and only one must be ON for any given perio...

Page 20: ...cooling heating mode Repress ON OFF button to quit the compulsive running and stop the operation of the air conditioner When any fault appears consult the fault code of line control or the flashing times for LED5 of computer panel of indoor units health lamp of receiving window of remote control and find out the faults as shown in the following table to remove all faults Indoor Unit Faults Failure...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ......

Reviews: