INSTALL THE DRAIN HOSE

Working procedure
1)   Install the attached drain hose to the drain port of the body. Install the hose band from 

the top of the hose within the graphic display area. Secure 

fi

 rmly with the hose band.

2)   Use vinyl adhesive agent to glue the drain piping (PVC pipe) / [

Φ

 3/4 in. (19 mm) I.D., 

Φ

 1-1/16 in. (27 mm) O.D.] which is prepared on site or piping socket. (Apply color 

adhesive agent evenly until the gauge line and seal)

3)   Check the drainage. 
4)   Install the heat insulation.
5)   Use the attached heat insulation to insulate the drain port and band parts of the body.

Top view

3/8 to 9/16 in. 
(10 to 15 mm)

Drain hose 
(Accessories)

Hose Band 
(Accessories)

Soft PVC side

Ensure there is no space

Drain pan

Side view

Applying 
area of 
adhesive

Hard PVC side

Joint pipe 
(Field supply)

Drain pipe (Field supply)

Φ

 3/4 in. (19 mm) [I.D.], 

Φ

 1-1/16 in. (27 mm) [O.D.]

3/16 in. (4 mm) or less 

Wrap the Drain hose insulation around the drain hose connection. 

Top view

Drain pan

Drain hose

3-15/16 in.
(100mm)

Drain hose insulation 
(Accessories)

Hose opening view

Wind the attached heat insulation 
around the hose band. Make sure the 
alignment is on top.

A. Floor console type

Be sure to arrange the drain hose so that it is leveled lower than the drain hose connect-
ing port of the indoor unit.

Drain hose

GOOD

PROHIBITED

Arrange the drain hose 
lower than this portion.

 

CAUTION

Do not install the unit so that the drain hose side is too high. Height A should be less 
than 3/16 in. (5 mm).

A

A

Drain hose

B. Under ceiling type

Be sure to arrange the drain hose so that it is leveled lower than the drain hose connect-
ing port of the indoor unit.

Drain hose

Arrange the drain hose 
lower than this portion.

GOOD

PROHIBITED

When drain hose is arranged backward.
Secure the drain hose with the VT wire.

Drain hose

VT wire 
hole

VT wire
(Accessories)

Pass the drain hose 
through here.

Cut the grille

Intake grille

Base (Bottom)

6. ELECTRICAL WIRING

]

 

WARNING

Electrical work must be performed in accordance with this Manual by a person 
certi

fi

 ed under the national or regional regulations. Be sure to use a dedicated circuit 

for the unit. An insuf

fi

 cient power supply circuit or improperly performed electrical work 

can cause serious accidents such as electric shock or 

fi

 re.

Before starting work, check that power is not being supplied to the all units.

Use the included connection cables and power cables or ones specified by the 
manufacturer. Improper connections, insuf

fi

 cient insulation, or exceeding the allowable 

current can cause electric shock or 

fi

 re.

For wiring, use the prescribed type of cables, connect them securely, making sure 
that there are no external forces of the cables applied to the terminal connections. 
Improperly connected or secured cables can cause serious accidents such as 
overheating the terminals, electric shock, or 

fi

 re.

Do not modify the power cables, use extension cables, or use any branches in the 
wiring. Improper connections, insufficient insulation, or exceeding the allowable 
current can cause electric shock or 

fi

 re.

Match the terminal board numbers and connection cable colors with those of the 
outdoor unit (or RB unit). Erroneous wiring may cause burning of the electric parts.

Securely connect the connection cables to the terminal board. In addition, secure the 
cables with wiring holders. Improper connections, either in the wiring or at the ends of 
the wiring, can cause a malfunction, electric shock, or 

fi

 re.

Always fasten the outside covering of the connection cable with the cable clamp. (If 
the insulator is chafed, electric discharge may occur.)

Securely install the electrical box cover on the unit. An improperly installed electrical 
box cover can cause serious accidents such as electric shock or 

fi

 re through exposure 

to dust or water.

Install sleeves into any holes made in the walls for wiring. Otherwise, a short circuit 
could result.

We suggest installing GFEB breakers or follow local electrical code. When installing 
this system, install using ground fault equipment breakers (GFEB) to reduce the risk 
of  leaking current which result in electric shock or potential 

fi

 re.

Always connect the earth (ground) cable.
Improper earthing (grounding) work can cause electric shocks.

Install the remote controller cables so as not to be direct touched with your hand.

Perform wiring work in accordance with standards so that the air conditioner can be 
operated safely and positively.

Connect the connection cable 

fi

 rmly to the terminal board. Imperfect installation may 

cause a 

fi

 re.

If the supply cable is damaged, it must be replaced by the manufacturer, its service 
agent or similarly quali

fi

 ed persons in order to avoid a hazard.

9367701124-03_IM.indb   Sec1:7

9367701124-03_IM.indb   Sec1:7

2013-10-25   13:00:42

2013-10-25   13:00:42

Summary of Contents for ABUA12TLAV

Page 1: ...nel only PART NO 9367701124 03 ABUA12TLAV ABUA14TLAV ABUA18TLAV ABUA24TLAV Fran ais MANUEL D INSTALLATION APPAREIL INT RIEUR type sol plafonnier Pour le personnel agr uniquement Espa ol MANUAL DE INST...

Page 2: ...the outdoor unit down with bolts and a metal frame Provide a suitable air baffle In a Snowy Area for Heat Pump type Systems Install the outdoor unit on a raised platform that is higher than drifting...

Page 3: ...dedicated tools and piping materials that have been manufactured specifically for R410A use Because the pressure of R410A refrigerant is approximately 1 6 times higher than the R22 failure to use ded...

Page 4: ...use refrigerant leakage Area that can cause combustible gas to leak contains suspended carbon fibers or flammable dust or volatile inflammables such as paint thinner or gasoline If gas leaks and settl...

Page 5: ...ccessories Special nut A Accessories Ceiling panel Spring washer Field supply M10 Nut Field supply M10 Nut Field supply 1 3 3 Installation the unit WARNING Install the air conditioner in a location wh...

Page 6: ...48 F 120 C Reverse cycle model only In addition if the humidity level at the installation location of the refrigerant piping is expected to exceed 70 install heat insulation around the refrigerant pip...

Page 7: ...iquid pipes Failure to do so may cause water leaks After checking for gas leaks insulate by wrapping insulation around the 2 parts Gas and Liquid of the indoor unit coupling using the coupler heat ins...

Page 8: ...ctric shock or fire Before starting work check that power is not being supplied to the all units Use the included connection cables and power cables or ones specified by the manufacturer Improper conn...

Page 9: ...37 to 90 Heat pump type indoor units Heat recovery type indoor units and RB units If the total number of units connected to the breaker exceeds 36 either add a 30mA breaker or use breakers with a grea...

Page 10: ...emote controller cable Shielded wire no film 1 3 16 in 30 mm 1 15 16 in 50 mm Transmission cable Remote controller cable For 3 wire type For 2 wire type 1 3 16 in 30 mm 1 3 16 in 30 mm When the 2 cabl...

Page 11: ...nd output cable with appropriate external dimension depending on the number of cables to be installed The wire connection should be separate from the power cable line Input select Use either one of th...

Page 12: ...rning ON output to the connected external heater can be set by changing Dip switch on PC board Dip switch SET2 SW3 Fan setting when ON is output to the external heater Explanation OFF Factory setting...

Page 13: ...s and the refrigerant circuit address can also be set up through the wireless remote controller Set it according to the following procedures when setting manually It can be set manually if the cover s...

Page 14: ...er 02 Shorter Filter indicator action 13 00 Enable Enable or disable the filter indicator Setting 02 is for use with a central remote controller 01 Disable 02 Display only on central remote controller...

Page 15: ...r lamp Orange FILTER indicator lamp Red MANUAL AUTO button 7 3 2 Checking the function settings Press and hold the MANUAL AUTO button on the indoor unit for 3 seconds to check the function settings It...

Page 16: ...r plate Left 1 Join the cover plates left and mount with screws Tapping screw M4 10 mm Accessories Cover plate Left Accessories 8 4 Mount the intake grille 1 Cut the right side of the intake grille Th...

Page 17: ...remote controller display If you use a wireless remote controller the lamp on the photodetector unit will output error codes by way of blinking patterns See the lamp blinking patterns and error codes...

Reviews: