User’s Manual – A16 J A18 J Series
Page 54
5.5.
Stopping the machine
5.5.1.
Normal stop
In normal operating conditions:
Release the controls to discontinue the operation and stop the machine. The machine will come to a complete
stop occurs within a default time set by the factory in order to ensure smooth braking.
By releasing the deadman pedal located on the platform, the operation is immediately stopped. Because of the
emergency character of this stop, the standstill of the machine can be quite sudden.
5.5.2.
Emergency stop button
If needed, the operator may stop all machine functions at once using either the controls on the platform or those on-
ground (control panel).
From the control panel on the basket,
Press the emergency stop button on the control panel to turn machine off;
By releasing the deadman pedal, the operation is immediately stopped. Braking may cause some sudden and
jerky motion in case of safety immediate stops.
From the control panel on ground:
By pressing the stop button on the ground control panel (if available), the machine (all models) and the engine
(models “D”, “ED”; “EB”) stop.
By pressing the power-discontinuance button (if available – “E” models), power is cut off (power circuit cut-out).
To retrieve normal operation:
From the control panel on the basket,
Turn the emergency stop button by 1/4 of a turn clockwise.
From the control panel on ground:
Turn the emergency stop button by 1/4 of a turn clockwise.
Pull out the mushroom button of the power circuit (if available) until it locks in position to power the unit again.
5.5.3.
Stopping the diesel engine
To stop the diesel engine:
From the control panel on the basket,
Turn the starter key to position “0”.
Otherwise, press the emergency stop button (mushroom).
From the control panel on ground:
Turn the starter key to position “0”.
Otherwise, press the emergency stop button (mushroom).
Do not stop the engine when the r.p.m. is high. Before stopping the engine wait until the r.p.m. is at
the lowest.
5.5.4.
Optional stopper of the 380V or 230V electrical pump
To stop the electrical pump (optional):
From the control panel on the basket,
Press the switch-off button;
Otherwise, press the emergency stop button (mushroom).
From the control panel on ground:
Press the emergency stop button (mushroom).
Summary of Contents for A16 J Series
Page 14: ...User s Manual A16 J A18 J Series Page 14...
Page 17: ...User s Manual A16 J A18 J Series Page 17...
Page 20: ...User s Manual A16 J A18 J Series Page 20...
Page 23: ...User s Manual A16 J A18 J Series Page 23...
Page 26: ...User s Manual A16 J A18 J Series Page 26...
Page 29: ...User s Manual A16 J A18 J Series Page 29...
Page 87: ...User s Manual A16 J A18 J Series Page 87...
Page 106: ...User s Manual A16 J A18 J Series Page 106 029 08 144...
Page 107: ...User s Manual A16 J A18 J Series Page 107 029 08 149...
Page 108: ...User s Manual A16 J A18 J Series Page 108 029 08 161...
Page 109: ...User s Manual A16 J A18 J Series Page 109 029 08 171...
Page 110: ...User s Manual A16 J A18 J Series Page 110 029 08 128...
Page 111: ...User s Manual A16 J A18 J Series Page 111 029 08 129...
Page 112: ...User s Manual A16 J A18 J Series Page 112 029 08 150...
Page 113: ...User s Manual A16 J A18 J Series Page 113 029 08 132...
Page 114: ...User s Manual A16 J A18 J Series Page 114 029 08 158...
Page 115: ...User s Manual A16 J A18 J Series Page 115 029 08 148...
Page 116: ...User s Manual A16 J A18 J Series Page 116 029 08 147...
Page 117: ...User s Manual A16 J A18 J Series Page 117...
Page 119: ...User s Manual A16 J A18 J Series Page 119...