10
TURNING THE COMPRESSOR ON
1. Plug the compressor into the
power supply.
2. Lift the On/Off button.
• The compressor will operate
until the reservoir is fully
pressurised and then shut down.
• The compressor will start up
again when the pressure in the
reservoir decreases.
CHECK THE SAFETY VALVE
To make sure that the safety valve works correctly:
1. Unscrew the knurled end and pull
it firmly outwards.
• Air will be released when you
pull the cap out and stop when
released.
2. If the valve does not operate in
this way, do not use the
compressor. The compressor must
be repaired by your dealer.
3. Screw the knurled end cap back
into position.
SET THE OUTPUT PRESSURE
Use the pressure regulator to set the
output pressure of the left hand outlet
valve.
• Turn clockwise to increase the
pressure.
• Turn counterclockwise to
decrease the pressure.
WARNING: DO NOT REMOVE OR TRY TO ADJUST THE SAFETY VALVE.
Summary of Contents for 1499520