9
Wiring diagram 2
L and N terminals are connected to live and neutral respectively and L and LT terminals are joined by the jumper.
The fan is always in SILENT mode. 24 Hours mode may not be activated. No matter of the signal from the motion sensor
the fan operated in SILENT mode. As humidity level increases the fan switches to MAX mode (by default) or continues
operation in SILENT mode (if adjusted by the user). After humidity level drops to standard level the fan reverts to SILENT mode.
L
I
L
I
L
T
L
T
L
L
N
N
N
N L
L
Fan operates
3
83/72 m /h (MAX)
3
40/33 m /h (MAX)
at air flow:
Humidity
change
Motion sensor
is activated
MAX (SILENT)
mode is activated
Fan operation in
Silent mode
Humidity
stabilization
Motion
if off
Signal to L
I
terminal
(light is on)
Humidity extraction
timer starts
(30-45-60 min)
Turn-o
ff
delay
timer starts
(5-15-30 min)
Signal to L
I
terminal
(light is off)
Turn-on delay
timer starts
(0-2-5 min)
Turn-on delay
timer starts
(0-2-5 min)