15
HUMIDITY EXTRACTION MODE ADJUSTMENT
The default time is 30 minutes.
After crossing the humidity set point the fan switches to higher
speed to extract excessive humidity. After the humidity level
stabilization the timer is activated and the fan runs for the set
time period to enable total extraction of the excessive humidity
and then it reverts to the previous operation mode.
If humidity rises less than by 20% for 10 minutes, the timer
countdown is 15 minutes.
Stabilization of humidity is understood as humidity change
no more than by 3% within 5 minutes.
To adjust the humidity extraction timer:
Press and hold the button "7CP" and press the button "2CP"
in cycles on th control panel.
This adjustment is not available from the remote controller.
Press and hold the button "7CP" and press the button "2CP"
on the control panel once to display the current settings of the
humidity sensor timer.
OFF-DELAY TIMER ADJUSTMENT
The default time is 5 minutes.
When the motion sensor is activated or the external switch is closed,
the fan operates for some time and then reverts to standby mode.
This time is adjustable.
To adjust the timer:
Press the button "2CP" in cycles on the control panel.
Press the buttons "9RC" (5, 15 or 30 respectively) on the remote
controller.
Press the button "2CP" on the control panel once to display the
current off-delay timer setting.
30
minutes
45
minutes
60
minutes
5
minutes
15
minutes
30
minutes
Summary of Contents for Aura Smart